Home
→
Departments
→
PPE, Safety & Test
→
Test & Measurement
→
Temperature & Humidity Measuring
→
Thermometer Calibrator Accessories
→
FLUKE Drywal Temp Calib, Plug-In, 95, 707 F 9100S-B-156
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Fluke
MFR#
9100S-B-156
FLUKE Drywal Temp Calib, Plug-In, 95, 707 F 9100S-B-156
Country of Origin
United States
Item
Drywall Temperature Calibrator
Temp. Range
36 Degrees to 375 Degrees C, 95 Degrees to 707 Degrees F
Power Required
115V AC ( +/-10%), 55/65 Hz
Search Similar Products
Uncheck any specs you want to ignore
Description
Drywall Temperature Calibrator, Handheld Dry-Well, Fluke 9100S, 95 Degrees to 707 Degrees F/35 Degrees to 375 Degrees C, Temperature Set Points -10 Degrees C, 375 Degrees C, Calibration Details Data at 50 Degrees C, 100 Degrees C, 150 Degrees C, 200 Degrees C, 250 Degrees C, 300 Degrees C and 375 Degrees C, Hot Block Temperature Range 95 to 707 F, 35 to 375 C, Interface RS-232, 2 1/4 in H x 4 29/32 in W x 6 7/64 in D
Technical Specifications
Country of Origin
United States
Item
Drywall Temperature Calibrator
Temp. Range
36 Degrees to 375 Degrees C, 95 Degrees to 707 Degrees F
Power Required
115V AC ( +/-10%), 55/65 Hz
Calibration Certificate
NIST
Includes
Instructions
Temp. Stability
+/-0.07 Degrees C at 50 Degrees C; +/-0.1 Degrees C at 100 Degrees C; +/-0.3 Degrees C at 375 Degrees C
Temp. Accuracy
+/-0.25 Degrees C at 100 Degrees C, +/-0.25 Degrees C at 50 Degrees C, +/-0.5 Degrees C at 375 Degrees C, +/-0.45 Degrees F at 122 Degrees F, +/-0.9 Degrees F at 707 Degrees F
Removable Inserts
No
Interface
RS-232
Typical Cooling Time
14 min (375 Degrees to 100 Degrees C)
Power Source Details
115V AC, 230V AC
Stabilization Time
5 min
Includes NIST-Traceable Certificate
Yes
Power Source
Plug-In
Display Resolution
0.1 Degrees F
Set Point Style
Adjustable
Typical Uniformity
+/-0.2 Degrees C
Brand and Series
Fluke 9100S
Typical Heating Time
9.5 min (35 Degrees to 375 Degrees C)
Interchangeable Insert
Yes
Calibrator Weight
2 lb
Stability
+/-0.07 Degrees C at 50 Degrees C, +/-0.1 Degrees C at 100 Degrees C, +/-0.3 Degrees C at 375 Degrees C
Temperature Accuracy
+/-0.25 Degrees C (at 100 Degrees C), +/-0.25 Degrees C (at 50 Degrees C), +/-0.45 Degrees F (at 122 Degrees F), +/-0.5 Degrees C (at 375 Degrees C), +/-0.9 Degrees F (at 707 Degrees F)
With Process Connections
No
Hot Block Temperature Range
95 to 707 F, 35 to 375 C
Calibrator Accuracy
+/-0.25 Degrees C at 100 Degrees C, +/-0.25 Degrees C at 50 Degrees C, +/-0.5 Degrees C at 375 Degrees C
Calibrator Type
Handheld Dry-Well
Calibration Details
Data at 50 Degrees C, 100 Degrees C, 150 Degrees C, 200 Degrees C, 250 Degrees C, 300 Degrees C and 375 Degrees C
Temperature Range
95 Degrees to 707 Degrees F/35 Degrees to 375 Degrees C
Similar Products
Fluke
FLUKE Stem Insert, 1/8 In 3102-2
3102-2
Fluke
FLUKE Stem Insert, 3/8 In 3102-6
3102-6
Fluke
FLUKE Stem Insert, 1/4 In 3102-4
3102-4
Fluke
FLUKE Drywell Temperature Calibrator, 9140 Series, Field Dry-Well, 95 to 662 Degrees F, Single Well 9140-A-156
9140-A-156
Fluke
FLUKE Stem Insert, 5/16 In 3102-5
3102-5
Fluke
FLUKE Stem Insert, 1/16 In 3102-1
3102-1
Kern
KERN Temperature calibration set consisting DAB-A01.
DAB-A01.
Kern
KERN Temperature calibration set consisting DBS-A01.
DBS-A01.
Can't find it?
We source what you need.