Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → PPE, Safety & Test → Test & Measurement → Temperature & Humidity Measuring → Infrared Thermometers → FLUKE Infrared Thermometer, Single Dot Laser Sighting Adjustable 0.10 to 1.00, Backlit LCD FLUKE-59 MAX +
FLUKE Infrared Thermometer, Single Dot Laser Sighting Adjustable 0.10 to 1.00, Backlit LCD FLUKE-59 MAX +
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Fluke
MFR# FLUKE-59 MAX +

FLUKE Infrared Thermometer, Single Dot Laser Sighting Adjustable 0.10 to 1.00, Backlit LCD FLUKE-59 MAX +

Country of Origin Malaysia
Item Infrared Thermometer
Temp. Range (F) - Infrared -22 Degrees to 932 Degrees
Emissivity Adjustable 0.10 to 1.00

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Infrared Thermometer, Laser Sighting Type Single Dot, Secondary Measuring Method No Secondary Measuring Method, Emissivity Adjustability Adjustable, Distance To Spot Ratio 10:1, Alert Type Digital Display, Sound, Field of View Not Applicable, Minimum Emissivity Setting 0.10, Maximum Emissivity Setting 1.00, Minimum Temperature Measured Degrees F -22 Degrees F, Maximum Temperature Measured Degrees F 932 Degrees F, Minimum Operating Temperature Degrees F 32 Degrees F

Technical Specifications

Country of Origin Malaysia
Item Infrared Thermometer
Temp. Range (F) - Infrared -22 Degrees to 932 Degrees
Emissivity Adjustable 0.10 to 1.00
Temp. Accuracy (F) - Infrared +/-1.0% or +/-2.0 Degrees Whichever is Greater
Temp. Accuracy (C) - Infrared +/-1.5% or +/-1.5 Degrees Whichever is Greater
Laser Sighting Single Dot
Calibration Certificate Included No
Data Logging - Instrument No
Display - IR Camera Backlit LCD
Standards 61326-1 EN 61326-2, EN/IEC 61010-1, FDA and EN 60825-1 Class II, IEC 68-2-27, IEC 68-2-6, IEC 60529
Memory Max/Min/Avg/Dif
Repeatability +/-1.0% of Reading or +/-2 Degrees F
Data Logging No
Memory - Instrument Avg., Dif., Max., Min
Accuracy +/-1.5 Degrees C or +/-1.5%
Temperature Alarm - Thermometer High, Low
Data Hold Yes
Display Backlit LCD
Temp. Range (C) -30 Degrees to 500 Degrees C
Operating Temp. Range 32 Degrees to 122 Degrees F
Item - Infrared Thermometer Infrared Thermometer
Response Time 500 msec
Temp. Range (F) -22 Degrees to 932 Degrees F
Laser Sighting - Infrared Single Dot
Trigger Lockable
Resolution 0.2 Degrees F/0.1 Degrees C
Alarm High/Low
Spectral Response - Infrared 8.0 to 14.0um
Calibration Certificate No
Can't find it?
We source what you need.
Bookmarks
Recently Viewed
Compare