RED LION Frequency to Analog Converter, 24V, 17mA IFM0001
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Red Lion
MFR# IFM0001

RED LION Frequency to Analog Converter, 24V, 17mA IFM0001

Country of Origin Denmark
Item Frequency to Analog Converter
Output Current - Maximum 20 mA
Features 2-Point Process Calibration, Advanced Configurable Input Limits for Increased Safety, All Terminals are Over-Voltage Protected (24 Vdc), Polarity Protected and Short-Circuit Protected, Linearization: Linear or Square Root Function, Measures Frequencies upto 100 KHz, Output Relay with Windows, Setpoint and Latch Functionality, Simulation of Process Value During Commissioning and Maintenance

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Frequency to Analog Converter, Mounting Style DIN Rail, Number of Channels Not Applicable

Technical Specifications

Country of Origin Denmark
Item Frequency to Analog Converter
Output Current - Maximum 20 mA
Features 2-Point Process Calibration, Advanced Configurable Input Limits for Increased Safety, All Terminals are Over-Voltage Protected (24 Vdc), Polarity Protected and Short-Circuit Protected, Linearization: Linear or Square Root Function, Measures Frequencies upto 100 KHz, Output Relay with Windows, Setpoint and Latch Functionality, Simulation of Process Value During Commissioning and Maintenance
Input Current - Maximum 17 mA
Input Voltage - Maximum 24 V DC
Power Required - Maximum 2.6 W
Output Voltage - Minimum 3.5 V DC
Output Current - Minimum 4 mA
Mounting Style DIN Rail
Output Voltage - Maximum 28 V DC
Overall Width 0.93 in
Overall Depth 4.09 in
Overall Height 4.29 in
Fits Chest Size 2-Point Process Calibration, Advanced Configurable Input Limits for Increased Safety, All Terminals are Over-Voltage Protected (24 Vdc), Polarity Protected and Short-Circuit Protected, Linearization: Linear or Square Root Function, Measures Frequencies upto 100 KHz, Output Relay with Windows, Setpoint and Latch Functionality, Simulation of Process Value During Commissioning and Maintenance