FLUKE Temp Calibrator, to2498 Degrees F, NIST Fluke-724
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Fluke
MFR# Fluke-724

FLUKE Temp Calibrator, to2498 Degrees F, NIST Fluke-724

Country of Origin Malaysia
Item Handheld Temperature Calibrator
Includes Instructions, Test Clips, Test Leads
Display Multiline LCD

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Handheld Temperature Calibrator, Sensor Type RTD, Thermocouple, +/-0.005 Percent of Range per Degrees C from -10 Degrees to 18 Degrees C, 28 Degrees to 55 Degrees C, -328 Degrees to 1,472 Degrees F/-200 Degrees to 800 Degrees C (RTD), -328 Degrees to 2,498 Degrees F/-200 Degrees to 1,370 Degrees C (Thermocouple)

Technical Specifications

Country of Origin Malaysia
Item Handheld Temperature Calibrator
Includes Instructions, Test Clips, Test Leads
Display Multiline LCD
Loop Supply Voltage 24V DC
Accuracy Dependent on Thermocouple or RTD Type
RTD Type Ni 120, Pt 100 (385), Pt 200 (385), Pt 500 (385), Pt 1000 (385), Pt 100 (393) and Pt 100 (JIS)
Powered By (4) AA batteries
Current Measurement Range 0 to 24mADC
RTD Temperature Range -328 Degrees to 1,472 Degrees F, (-200 Degrees to 800 Degrees C) (Dependent on Type RTD)
Voltage Measurement Range 0V DC to 30V DC
Resistance Source 15 to 3200 ohm
Source Voltage -10mV to 10V DC
Calibration Certificate NIST
Thermocouple Temperature Range -328 Degrees to 2,498 Degrees F, (-200 Degrees to 1,370 Degrees C) (Dependent on Thermocouple Type)
Max. Loop Current 22mADC
Thermocouple Type J , K, T, E, R, S, B, L, U, N, XK and BP
Source/Simulate T, Ohms, V
Resistance Measurements 0 to 3200 ohm
Measurement Functions Current, Resistance, Temperature, Voltage
Millivolt Range 0 to 100mV DC
Sensor Temperature Range -20 Degrees to 1,750 Degrees C (Type R), -20 Degrees to 1,750 Degrees C (Type S), -200 Degrees to 1,200 Degrees C (Type J), -200 Degrees to 1,370 Degrees C (Type K), -200 Degrees to 13,000 Degrees C (Type N), -200 Degrees to 400 Degrees C (Type T), -200 Degrees to 600 Degrees C (Type U), -200 Degrees to 900 Degrees C (Type L), -200 Degrees to 950 Degrees C (Type E), 600 Degrees to 1,800 Degrees C (Type B)
Number of Digits 5
Sensor Minimum Temperature C 600 Degrees C (Type B), -200 Degrees C (Type E), -200 Degrees C (Type J), -200 Degrees C (Type K), -200 Degrees C (Type L), -200 Degrees C (Type N), -20 Degrees C (Type R), -20 Degrees C (Type S), -200 Degrees C (Type T), -200 Degrees C (Type U)
Accuracy - Measure 0.02% +2 Counts
Auto Power Off Yes
Accuracy - Source 0.025 % +1 Count
RTD Temperature Range C -200 Degrees to 800 Degrees C
Sensor Type RTD, Thermocouple
Thermocouple Temperature Range C -200 Degrees to 1,370 Degrees C