Home
→
Departments
→
PPE, Safety & Test
→
Test & Measurement
→
Process Monitoring
→
Process Calibrators
→
FLUKE Multifunction Calibrator FLUKE-754/750SW BU
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Fluke
MFR#
FLUKE-754/750SW BU
FLUKE Multifunction Calibrator FLUKE-754/750SW BU
Country of Origin
United States
Item
Process Calibrator
Includes
(2) AC280 Hook Clips, (3) Extended Tooth Alligator Clips, (3) TP220 Test Probes, 754HHC HART Communications Cable, Battery Charger, Carrying Case, USB Cable
Standards
ASNI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1-92, EN 610-1:1993, UL3111
Search Similar Products
Uncheck any specs you want to ignore
Description
Multifunction Calibrator, Voltage Measurement Range 0 to 300V AC/V DC, Loop Supply Voltage 26 V, Intrinsically Safe No, Pressure Modules All Fluke 700 Series modules, Measurement Functions F, mA, Ohms, P, T, V, Source Current 0 to 24mA DC, Current Measurement Range 0 to 24mA DC, Basic DC Accuracy +/- 0.05 Percent + 0.05V, Thermocouple Temperature Range -25 Degrees to 250 Degrees C, Powered By Rechargeable Battery Pack
Technical Specifications
Country of Origin
United States
Item
Process Calibrator
Includes
(2) AC280 Hook Clips, (3) Extended Tooth Alligator Clips, (3) TP220 Test Probes, 754HHC HART Communications Cable, Battery Charger, Carrying Case, USB Cable
Standards
ASNI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1-92, EN 610-1:1993, UL3111
Interface
USB
Loop Supply Voltage
26 V
Powered By
Rechargeable Battery Pack
Current Measurement Range
0 to 24mA DC
Thermocouple Temperature Range
-25 Degrees to 250 Degrees C
Voltage Measurement Range
0V AC to 300V AC, 0V DC to 300V DC
Basic DC Accuracy
+/- 0.05% + 0.05V
Source Current
0 to 24mA DC
Intrinsically Safe
No
Measurement Functions
F, mA, Ohms, P, T, V
Thermocouple Type
B, BP, C, E, J, K, L, N, R, S, T, U, XK
Pressure Modules
All Fluke 700 Series modules
Shop By
Hot Buys
Source Frequency - Maximum
50 kHz
CAT Safety Rating
CAT II 300V
Frequency Measurement - Minimum
11.01 kHz
Voltage Measurement - Minimum
3 V AC/DC
Voltage Measurement - Maximum
300 V AC/DC
Communication Protocol
HART
Frequency Measurement - Maximum
50 kHz
Parameters Measured
AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance
Thermocouple Temperature - Maximum
1,472 Degrees F
Intrinsic Safety
Not Specified Intrinsically Safe
Current Measurement - Maximum
110 mA
Current Measurement - Minimum
30 mA
Calibration Certificate Type
NIST
Similar Products
Rothenberger
ROTHENBERGER Precision Test Pump, 860 psi, 1/2 in, Steel 60200
60200
Fluke
FLUKE Temp Calibrator, to2498 Degrees F, NIST FLUKE-714B
FLUKE-714B
Fluke
FLUKE Documenting Process Calibrator, HART Fluke-754
Fluke-754
Extech
EXTECH Process Calibrator, Current/Voltage, 20V PRC15
PRC15
Extech
EXTECH Temperature Calibrator, to2498 Degrees F PRC30
PRC30
Extech
EXTECH Calibrator, 0 to 10VDC, 0 to 24mADC 412355A
412355A
Fluke
FLUKE Loop Calibrator FLUKE-709
FLUKE-709
Fluke
FLUKE Temperature Calibrator, RTD, NIST FLUKE-712B
FLUKE-712B
Can't find it?
We source what you need.