Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → PPE, Safety & Test → Test & Measurement → Process Monitoring → Process Calibrators → FLUKE Drywal Temp Calib, Plug-In 9142-A-P-156
FLUKE Drywal Temp Calib, Plug-In 9142-A-P-156
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Fluke
MFR# 9142-A-P-156

FLUKE Drywal Temp Calib, Plug-In 9142-A-P-156

Country of Origin United States
Item Drywall Temperature Calibrator
Includes 9142 Field Metrology Well, Insert for Configuration Ordered, Power Cord, RS-232 Cable, User Guide, Technical Manual CD, Report of Calibration, Calibration Label, 6-pin DIN Connector, Test Lead Kit, Well Insulator, Clamp-on ferrites (3), Tongs (insert removal tool), 9930 Interface-it Software and User's Guide
Display LCD

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Drywell, Field Metrology Well, Fluke 9142, -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C, Calibration Details NVLAP Accredited Calibration Included, Interface RS-232, Number of Set Points Variable, 11 13/32 in H x 7 5/16 in W x 11 39/64 in D

Technical Specifications

Country of Origin United States
Item Drywall Temperature Calibrator
Includes 9142 Field Metrology Well, Insert for Configuration Ordered, Power Cord, RS-232 Cable, User Guide, Technical Manual CD, Report of Calibration, Calibration Label, 6-pin DIN Connector, Test Lead Kit, Well Insulator, Clamp-on ferrites (3), Tongs (insert removal tool), 9930 Interface-it Software and User's Guide
Display LCD
Standards NVLAP Accredited
Interface RS-232
Loop Supply Voltage 24V DC
Accuracy +/-0.01 Degrees C
RTD Type NI-120, 385, 3892, JIS
Application Field Testing
RTD Temperature Range -196 Degrees to 660 Degrees C
Thermocouple Type C, E, J, K, L, M, N, R, S, T, U
Max. Loop Current 24 mA
Thermocouple Temperature Range 0 Degrees to 1,480 Degrees C (type S)
Calibration Certificate NVLAP accredited
Agency Compliance CE, CSA, C-TICK, ROHS, WEEE
Resistance Sensing Current Characteristics 0.02% at 2 mV; Cal 4-22 mA, Spec 4-24 mA
Temperature Range -196 Degrees to 660 Degrees C, 0 Degrees to 1,480 Degrees C
Reference Input Temperature Characteristics +/-0.010 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 150 Degrees C, +/-0.030 Degrees C at 200 Degrees C, +/-0.040 Degrees C at 350 Degrees C, +/-0.050 Degrees C at 420 Degrees C, +/-0.070 Degrees C at 660 Degrees C
RTD Temperature Range C -196 Degrees to 660 Degrees C
Typical Cooling Time 15 min (23 Degrees to -25 Degrees C), 25 min (150 Degrees to -23 Degrees C)
Stability +/-0.01 Degrees C
Thermocouple mV Characteristics 0.025% + 0.01 mV at -10 to 75 mV
Calibrator Type Field Metrology Well
Typical Heating Time 16 min (23 Degrees to 140 Degrees C), 23 min (23 Degrees to 150 Degrees C), 25 min (-25 Degrees to 150 Degrees C)
Sensor Type RTD, Thermocouple
Thermocouple Temperature Range C 0 Degrees to 1,480 Degrees C
Display Resolution 0.01 Degrees F
Reference Input Resistance Characteristics +/--0.0025 ohm Accuracy (0 to 42 ohm), +/-60 ppm of Reading Accuracy (42 to 400 ohm)
Current mA Characteristics 0.02% + 2 mV Accuracy/4 to 22 mA, 4 to 24 mA Range