FLUKE Drywal Temp Calib, Plug-In, -139, 284 F 9190A-F-P-156
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Fluke
MFR#
9190A-F-P-156
FLUKE Drywal Temp Calib, Plug-In, -139, 284 F 9190A-F-P-156
Country of Origin
United States
Item
Drywall Temperature Calibrator
Includes
6 ft Main Power Cord, 9190 Insert F, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
Display
LCD
Search Similar Products
Uncheck any specs you want to ignore
Description
Drywell, Field Metrology Well, Fluke 9190A, -139 Degrees to 284 Degrees F/-95 Degrees to 140 Degrees C, Interface RS-232, USB Cable, Number of Set Points Variable, 18 13/16 in H x 8 in W x 14 29/32 in D
Technical Specifications
Country of Origin
United States
Item
Drywall Temperature Calibrator
Includes
6 ft Main Power Cord, 9190 Insert F, 9930 Interface-It Calibration Software and Users Guide, Getting Started Manual, Insert Removal Tool, Product CD, Report of Calibration and Calibration Label, USB Cable, Well Insulator Cap
Display
LCD
Standards
IEC 61010-1, Installation Category II, Pollution degree 2, IEC 61326-1: Basic
Interface
RS-232, USB Cable
Loop Supply Voltage
24V DC
Accuracy
+/-0.2 Degrees C Full Range
RTD Type
4 Wire, 3 Wire, 2 Wire
Application
Blood Banks, Cold Rooms, Freeze Dryers, Laboratory Refrigerators, Medical Freezers, Sterilizers (Autoclaves)
RTD Temperature Range
-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Thermocouple Temperature Range
-139 Degrees to 284 Degrees F (-95 Degrees to 140 Degrees C)
Max. Loop Current
4 to 20mA
Calibration Certificate
yes
Thermocouple Type
C, E, J, K, L, M, N, R, S, T, U
Agency Compliance
EU Directives, CSA, Australian EMC Requirements
Power Source
Plug-In
Typical Uniformity
+/-0.05 Degrees C
Calibrator Accuracy
+/-0.2 Degrees C
Probe Connection Types
(1) 4-Terminal RTD Input, (1) Miniature Connectors (ASTM E1684)
Stabilization Time
10 min
Display Resolution
0.01 Degrees F
Brand and Series
Fluke 9190A
Reference Input Temperature Characteristics
+/-0.010 Degrees C at -95 Degrees C, +/-0.013 Degrees C at -25 Degrees C, +/-0.015 Degrees C at 0 Degrees C, +/-0.020 Degrees C at 50 Degrees C, +/-0.025 Degrees C at 140 Degrees C
Current mA Characteristics
0.02% + 0.002 mA Accuracy/4 to 22 mA, 4 to 24 mA Range
Typical Heating Time
40 min (-95 Degrees to 140 Degrees C)
Display Temperature Accuracy
+/-0.2 Degrees C
Reference Junction Temperature Characteristics
+/- 0.35 Degrees C Accuracy at Ambient Temperature of 13 Degrees to 33 Degrees C
Typical Cooling Time
60 min (140 Degrees to 23 Degrees C), 80 min (23 Degrees to -90 Degrees C), 90 min (23 Degrees to -95 Degrees C)
RTD Temperature Range F
-139 Degrees to 284 Degrees F
Similar Products
Rothenberger
ROTHENBERGER Precision Test Pump, 860 psi, 1/2 in, Steel 60200
60200
Fluke
FLUKE Temp Calibrator, to2498 Degrees F, NIST FLUKE-714B
FLUKE-714B
Fluke
FLUKE Documenting Process Calibrator, HART Fluke-754
Fluke-754
Extech
EXTECH Process Calibrator, Current/Voltage, 20V PRC15
PRC15
Extech
EXTECH Temperature Calibrator, to2498 Degrees F PRC30
PRC30
Extech
EXTECH Calibrator, 0 to 10VDC, 0 to 24mADC 412355A
412355A
Fluke
FLUKE Loop Calibrator FLUKE-709
FLUKE-709
Fluke
FLUKE Temperature Calibrator, RTD, NIST FLUKE-712B
FLUKE-712B