Home
→
Departments
→
Mechanical
→
Sanitary
→
Gauges
→
Level Switches & Transmitters
→
FLOWLINE EchoPro® LR41 Solid Level Sensor Transmitter w/ 26 GHz Pulse Radar, 229.7 ft. Range, Intrinsically Safe LR41-5321-44-00
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Flowline
MFR#
LR41-5321-44-00
FLOWLINE EchoPro® LR41 Solid Level Sensor Transmitter w/ 26 GHz Pulse Radar, 229.7 ft. Range, Intrinsically Safe LR41-5321-44-00
Range
12 in. to 229.7 ft. (30 cm to 70 m)
Accuracy
± 1mm
Pressure
Atmospheric
Dead band
12 in. (30 cm)
Search Similar Products
Uncheck any specs you want to ignore
Description
EchoPro® LR41 intrinsically safe 26 GHz. Pulse radar transmitter provides continuous level measurement up to 49.2 ft. (15m) range, with a 4-20 mA analog and Hart digital signal output. The sensor is configured by a integral push button display module or HART communicator. This non-contact solids level sensor is for dry solid media including aggregates, grains, pellets, powders, and building materials. Applications include bins, transfer stations and crushers. This sensor is for easy process conditions with minimal dust and installation with and adjustable mounting bracket or gimbal flange. Features Configuration via push button display or HART communicator Rugged 316L stainless steel antenna and process mount Gimbal flange for easy positioning with the angle of repose LCD displays level in feet or meters with percent of span bar Optional display mode indicates the echo signal return curve Fail-safe diagnostics with selectable signal fail-safe outputs Recognition, storage and rejection of false echo signal returns 26 GHz. pulse radar IP67 stainless enclosure with polycarbonate display window 12 in.(30cm) dead band enables utilization Specifications 1 1/2 in. NPT process mount 4 in. ANSI Gimbal flange Range: 12 in. to 229.7 ft. (30 cm to 70 m) 26 GHz frequency Accuracy: ± 1mm Stainless steel transducer HART 7 & 4-20mA, two-wire signal output Pressure: Atmospheric Dead band: 12 in. (30 cm) Configuration: Push button, HART 7 Display: LCD, dot matrix Display units: feet and meters Display bar: Percent of span Display graph: Echo signal curve Memory: Non-volatile 8° beam angle Supply voltage: 21.6 to 26.4V DC Max. Consumption: 22.5 mA Signal output: 4-20 mA, two-wire, HART 7 Signal invert: 4-20 mA, 20-4 mA Temp. comp: Automatic Process temp.: -40° to 392° F (-40° to 200°C) Storage temp.: -40° to 176° F ( -40° to 80° C) Enclosure: Stainless steel w/ silicone gasket IP67 rated enclosure Display window: Polycarbonate Conduit entrance: (1) 1/2 in. NPT connectors Classification: Intrinsically safe Certification: FCC Complies to CE, RoHS Downloads Datasheet (PDF Download) Quick Start (PDF Download) Manual (PDF Download)
Technical Specifications
Range
12 in. to 229.7 ft. (30 cm to 70 m)
Accuracy
± 1mm
Pressure
Atmospheric
Dead band
12 in. (30 cm)
Configuration
Push button, HART 7
Display
LCD, dot matrix
Display units
feet and meters
Display bar
Percent of span
Display graph
Echo signal curve
Memory
Non-volatile
Supply voltage
21.6 to 26.4V DC
Max. Consumption
22.5 mA
Signal output
4-20 mA, two-wire, HART 7
Signal invert
4-20 mA, 20-4 mA
Temp. comp
Automatic
Process temp.
-40° to 392° F (-40° to 200°C)
Storage temp.
-40° to 176° F ( -40° to 80° C)
Enclosure
Stainless steel w/ silicone gasket
Display window
Polycarbonate
Conduit entrance
(1) 1/2 in. NPT connectors
Similar Products
Flowline
FLOWLINE EchoPod® DL14 Ultrasonic Multi-Function Liquid Level Sensor, 1 in. NPT, 4.1 ft. Range DL14-00
DL14-00
Flowline
FLOWLINE USB FOB for WebCal Sensor Configuration LI99-2001
LI99-2001
Flowline
FLOWLINE EchoTouch® US01 & US03 Reflective Ultrasonic Non-Contact Liquid Level Sensor Transmitter, 2 in. NPT, Intrinsically Safe US01-0001-00
US01-0001-00
Flowline
FLOWLINE DataLoop® LI23 Level Sensor Indicator & Display with Alarms w/ 2 Relays, 4-20mA Repeater LI23-1211
LI23-1211
Flowline
FLOWLINE Switch-Tek® LV42 Large Sump Float Level Switch SPDT 10 (3) A 250V, 20 ft. cable LV42-7201
LV42-7201
Flowline
FLOWLINE Switch-Tek® LV41 Small Sump Float Level Switch, SPDT 10 (8) A 250V, w/ 20 ft. Cable LV41-7201
LV41-7201
Flowline
FLOWLINE EchoTouch® US06 Reflective Ultrasonic Liquid Level Sensor Transmitter, 19.6 Ft. Range, 2 in. NPT, Intrinsically Safe US06-0001-00
US06-0001-00
Flowline
FLOWLINE EchoPod® DL24 Ultrasonic Multi-Function Liquid Level Sensor Transmitter, 1 in. NPT, 9.8 ft. Range DL24-00
DL24-00
Can't find it?
We source what you need.