TELEDYNE GD10P Infrared Gas Detector For Methane (CH4) - 100% LEL (4.4% Vol.) GD10P LEL
Verified Sourcing
Import & Local Stock
Flexible Payment
Search Similar Products
Uncheck any specs you want to ignore
Description
DescriptionThe GD10P series of infrared gas detectors has set the standard in the areas of performance, safety, response time, stability and maintenance.The GD10P differs from all other infrared gas detectors because it uses a silicon-based solid-state infrared source instead of a filament. The patented Sim-SourceTM solid state IR light source is extremely stable. The intensity of the IR light does not deteriorate over time like a filament, therefore the GD10P never requires calibration for compensation of this signal. In addition to the stability, the Sim-SourceTM light has the best longevity in the industry and is covered by a15-year full replacement warranty. All optical components are mounted on single metal platform which provides stability of measurements even in high vibration environments. The dual path-length design compensates for temperature, humidity, and particulates in the environment. The heated optics eliminate the adverse effects of moisture in high humidity applications. There are also two user-adjustable levels of dirty optics indications, a warning and an alarm. The GD10P is so robust that it will operate and alarm with up to 70% optics signal blockage. Optics can be easily cleaned with a moist cloth and there is no need to declassify the area for this service procedure. The GD10P also excels with the ultra-fast response times, responding to gas exposures in only a few seconds. The patented dual layer weather shield design allows gas to rapidly enter and exit the measurement chamber. Since the weather shield contains no sinters or mechanical filters, it provides the same fast response under any conditions: from stormy offshore platforms to wind-swept desert applications. Response times can be adjusted through a HART hand-held. Features An industry standard HART® interface is used for configuration of special faultlevels as well as access to extended maintenance data Integral termination compartment for reduced installation time: the unit is ready out of the box Low-power consumption which reduces load on UPS Independently heated mirror and lens for high performance detection in harsh environmental conditions Life-safety performance approved; ATEX & CSA 15 year warranty IR sources - solid state optics No field recalibration Dual skin weather protector no filters / gauzes or sinters Planned maintenance with HART SIL 2/3 certified SpecificationsBrand: TeledyneSeries: GD10PPart Number: GD10P LELSensor: Infrared Material (Housing): Stainless SteelCertifications / Approvals: ATEX / IECEx / INMETRO - II 2 G / Ex db eb IIC T6 Gb; CSA - C22.2 No 152-M984 and ANSI 12.13.01-2000, Ex d e IIC T6 (for Canada only), Class I, Division 2, Groups A, B, C and D (USA and Canada); SIL 2 certified (software is SIL 3), ABS, MEDDisplay: No DisplayGas: GD10P CH4, Methane 100% LEL (4.4% Vol.), SS 316L, CSA, 4-20mA, sourceIngress Protection: IP66/IP67Accuracy: ±3% FS between 0-50 % reading ±5% FS between 50-100 % readingConfiguration: HART protocolInput Voltage: 24V DCIR-source: Solid stateOperating Humidity Range: 0- 100% RHResponse Time: T20 = 0.7 sec; T50 = 1.7 sec; T90 = 4 secSelf-Test: ContinuousTemperature Range: -40°C to +60°C (-40°F to +140°F) DownloadsSpecification Sheet (PDF Download) Product Literature (PDF Download)
Technical Specifications
Brand
: Teledyne
Series
: GD10P
Part Number
: GD10P LEL
Sensor
: Infrared
Material (Housing)
: Stainless Steel
Certifications / Approvals
: ATEX / IECEx / INMETRO - II 2 G / Ex db eb IIC T6 Gb; CSA - C22.2 No 152-M984 and ANSI 12.13.01-2000, Ex d e IIC T6 (for Canada only), Class I, Division 2, Groups A, B, C and D (USA and Canada); SIL 2 certified (software is SIL 3), ABS, MED
Display
: No Display
Gas
: GD10P CH4, Methane 100% LEL (4.4% Vol.), SS 316L, CSA, 4-20mA, source
Ingress Protection
: IP66/IP67
Accuracy
: ±3% FS between 0-50 % reading ±5% FS between 50-100 % reading
Configuration
: HART protocol
Input Voltage
: 24V DC
IR-source
: Solid state
Operating Humidity Range
: 0- 100% RH
Response Time
: T20 = 0.7 sec; T50 = 1.7 sec; T90 = 4 sec
Self-Test
: Continuous
Temperature Range
: -40°C to +60°C (-40°F to +140°F)
SKU
PSGD10PLEL
Manufacturer
Teledyne
Product Type
1 Gas, Methane (CH4)
Similar Products
Gas Clip Technologies
GAS CLIP TECHNOLOGIES Quick Disconnect for MGC Pump MGC-PUMP-QD
MGC-PUMP-QD
Gas Clip Technologies
GAS CLIP TECHNOLOGIES Infrared Detector, 4 Gas (H2S, O2, CO & LEL), 2 Months Run Time MGC
MGC
Fuel Quality Services
FUEL QUALITY SERVICES Bug Alert Fuel Test Kit w/ AB/YM Strips, 10 Test Pairs FQS-005
FQS-005
Teledyne
TELEDYNE GD10P Infrared Gas Detector For Carbon dioxide (CO2) - Up To 10,000 PPM GD10P CO2
GD10P CO2
Teledyne
TELEDYNE OLCT 100 IS Gas Detector, Flammable Gases, Intrinsically Safe w/ ATEX & M20 Cable Entry - 0 to 100% LEL (IEC) OLCT 100-ISMS21
OLCT 100-ISMS21
Teledyne
TELEDYNE OLCT 100 IS Gas Detector, Flammable Gases, Intrinsically Safe w/ ATEX & M20 Cable Entry - 0 to 100% LEL (ISO) OLCT 100-ISMS11
OLCT 100-ISMS11
Teledyne
TELEDYNE OLCT 100 IS Gas Detector, Methane (CH4), Intrinsically Safe w/ ATEX & M20 Cable Entry - 0 to 100% LEL (4.4% Vol) OLCT 100-IS21
OLCT 100-IS21
Teledyne
TELEDYNE OLCT 100 IS Gas Detector, Methane (CH4), Intrinsically Safe w/ ATEX & M20 Cable Entry - 0 to 100 % LEL OLCT 100-IS11
OLCT 100-IS11
Can't find it?
We source what you need.