OTIS INSTRUMENTS Omniguard Model 860 Aluminum Ultraviolet Infrared Flame Detector, Auto Self Test, Latching 860-00100
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Otis Instruments
MFR#
860-00100
OTIS INSTRUMENTS Omniguard Model 860 Aluminum Ultraviolet Infrared Flame Detector, Auto Self Test, Latching 860-00100
Model
Omniguard 860
Operating Temperature
-40°F to 185°F (-40°C to 85°C)
Nominal Voltage
24 VDC (Ripple Voltage <240mV)
Range
20 to 30 VDC
Search Similar Products
Uncheck any specs you want to ignore
Description
Otis Instruments Omniguard Model 860 Aluminum Ultraviolet Infrared Flame Detector
The Otis Instruments Omniguard Model 860 UV/IR Flame Detector is engineered for early detection of unwanted fires, sensing both ultraviolet and infrared radiation in the appropriate wavelengths. It uses the patented Omniguard Fire Event Analysis Algorithm to minimize false alarms and ensure reliable performance.
The detector includes an automatic self-test function that continuously monitors its ability to detect fires, alerting users if the system is impaired.
Note: Swivel mount (20856) included.Please call 1-855-758-3856 for other available configurations.
Features
Patented Fire Event Analysis (FEA) Algorithm for Superior False Alarm Immunity
Operating Temperature: -40°F to 185°F (-40°C to 85°C)
User-Selectable Sensitivities
Long Range Detection
Advanced Through-the-Lens Diagnostic Self-Test
Self-Contained, Explosion-Proof Enclosure
Field Configurable Relays and Sensitivity
State-of-the-Art Microprocessor Control with Proprietary Fire Library
Robust Weatherproof Enclosure for Indoor or Outdoor Applications
Widest Field of View in the Industry of 120°
High Intensity, Localized Indication of Fire or Fault
Economical No-Test Version Available
FM, CSA, IECEx and ATEX Approved
All Inclusive 3-Year Warranty on Parts and Labor
Specifications
Model: Omniguard 860
Operating Temperature: -40°F to 185°F (-40°C to 85°C)
Spectral Response:
UV Peak Sensitivities of 0,22 μm
Infrared Peak Sensitivities of 4.4 μm (Standard), and 2.9 μm and 4.4 μm (Dual Pass)
Nominal Voltage: 24 VDC (Ripple Voltage <240mV)
Range: 20 to 30 VDC
Power Consumption: 90 mA (Standby), 110 mA (Alarm), 250 mA (Auto and Manual Test)
Output:
Relay
Relays (2): Fire, Trouble, Dry Contacts, Hermetically Sealed
Rated: 2 A at 28 VDC (User Selects NO or NC)
Fire Relay: Latching (Non-Latching Optional)
Current Loop (Standard Version): 0 to 20 mA Output
20 mA = Fire
16 mA = UV or IR Presence
4 mA = Ready
0 mA = 20
Digital Output: Programmable RS-485 Modbus Serial Output
Product Dimensions: 4.5 in. H x 5.5 in. W x 6 in. D
Total Weight: 5 lbs. (Aluminum)
Conduit Entry: 3/4-14 NPTF (M20-1.5 Optional)
Optional Accessories:
Portable Test Unit - Model 545 / 545
Air Shield Assembly Kit - No. 8001023
Rain Shield - No. 23546
Pole Mount for Swivel Mount - No. 26803
Certifications & Approvals
Class I, Division 1, Groups B, C & D (Explosion Proof)
Class II, Division 1, Groups E, F & G (Dust Ignition Proof)
NEMA 4X Weatherproof, Dust-Tight, Watertight
CE0081 Ex d II 2 G/D
Ex d IIB+H2 T5 Gb for Gas on 660-0XXXX
EX tb IIIC T100°C Db IP6X for Dust on 660-0XXXX
Ex d IIB+H2 T4 Gb for Gas on 660-1XXXX
EX tb IIIC T1 135°C Db IP6X for Dust on 660-1XXXX
Copper-Free Aluminum Housing Conversion Coated to MIL-C-5541, Class 3 (White) - Standard
Stainless Steel Housing with Passive Finish per MIL-5-5002C, Type 1 (Optional)
Downloads
Omniguard Model 860 Data Sheet (PDF Download)
Omniguard Swivel Mount Data Sheet (PDF Download)
Technical Specifications
Model
Omniguard 860
Operating Temperature
-40°F to 185°F (-40°C to 85°C)
Nominal Voltage
24 VDC (Ripple Voltage <240mV)
Range
20 to 30 VDC
Power Consumption
90 mA (Standby), 110 mA (Alarm), 250 mA (Auto and Manual Test)
Relays (2)
Fire, Trouble, Dry Contacts, Hermetically Sealed
Rated
2 A at 28 VDC (User Selects NO or NC)
Fire Relay
Latching (Non-Latching Optional)
Current Loop (Standard Version)
0 to 20 mA Output
Digital Output
Programmable RS-485 Modbus Serial Output
Product Dimensions
4.5 in. H x 5.5 in. W x 6 in. D
Total Weight
5 lbs. (Aluminum)
Conduit Entry
3/4-14 NPTF (M20-1.5 Optional)
SKU
AOI86000100SWIV
Manufacturer
Otis Instruments
Weight
5.00 LBS
Similar Products
Otis Instruments
OTIS INSTRUMENTS Omniguard Model 760 Aluminum Multi-Spectrum Infrared Flame Detector, Auto Self Test, Latching 760-00100
760-00100
Otis Instruments
OTIS INSTRUMENTS Omniguard Model 660 Aluminum Ultraviolet Flame Detector, Auto Self Test, Latching 660-00100
660-00100
W.L. Walker
W.L. WALKER Flash Point Testing Mercury Thermometer GRID_WLW55016
GRID_WLW55016
W.L. Walker
W.L. WALKER Tag Closed-Cup Flash Point Tester 24440
24440
W.L. Walker
W.L. WALKER Pensky-Marten Flash Point Tester 24420
24420
W.L. Walker
W.L. WALKER Replacement Tag Closed-Cup Flash Point Tester Cup WLWL4X
WLWL4X
Gas Clip Technologies
GAS CLIP TECHNOLOGIES Quick Disconnect for MGC Pump MGC-PUMP-QD
MGC-PUMP-QD
Gas Clip Technologies
GAS CLIP TECHNOLOGIES Infrared Detector, 4 Gas (H2S, O2, CO & LEL), 2 Months Run Time MGC
MGC
Can't find it?
We source what you need.