Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Mechanical → Liquid Cooling → Gauges → Temperature Transmitters → DWYER Series HHT Hazardous Area Humidity/Temperature Transmitter, Intrinsically Safe DWYR8X
DWYER Series HHT Hazardous Area Humidity/Temperature Transmitter, Intrinsically Safe DWYR8X
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Dwyer
MFR# DWYR8X

DWYER Series HHT Hazardous Area Humidity/Temperature Transmitter, Intrinsically Safe DWYR8X

Relative Humidity Range 0 to 100% RH.
Temperature Range -40 to 140°F (-40 to 60°C).
Accuracy ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C).
Hysteresis ±1%.

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The Series HHT Hazardous Area Humidity/Temperature Transmitter takes accurate measurements in the harshest of environments. The explosion-proof model is offered with 4 to 20 mA output for humidity only. The intrinsically safe version is offered with 4 to 20 mA output for humidity and temperature, and do require an intrinsically safe barrier to meet hazardous area approvals. Applications: Process Monitoring, Offshore HVAC Monitoring, Dust & Grain Handling. Features FM approved explosion-proof and intrinsically safe models Temperature and relative humidity output models Some models include Integral LCD option. Specifications Relative Humidity Range: 0 to 100% RH. Temperature Range:-40 to 140°F (-40 to 60°C). Accuracy:±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C). Hysteresis: ±1%. Repeatability: ±0.1% typical. Temperature Limits:-40 to 140°F (-40 to 60°C). Storage Temperature:-40 to 176°F (-40 to 80°C). Compensated Temperature:-40 to 140°F (-40 to 60°C). Power Requirements: For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC. Output Signal: 4 to 20 mA 2 channels for humidity/temperature models (loop power on RH). Response Time: 15 electrical Connections: Screw terminal block. Conduit Connection: 1/2" female Updrift:<1% RH/year. RH Sensor: Capacitance polymer. Temperature Sensor: Solid state band gap. Housing Material: Aluminum. Display: Optional 2 line alpha numeric, 8 characters/line. Temperature display is °F/°C selectable. Display Resolution: RH: 0.1%; Temperature: 0.1°F (0.1°C).Weight:2 lb 8 oz (1134 g). Enclosure Ratingen 4X (IP66). Models HHT-EX: FM Explosion-proof, Class I Div. 1 Group B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 Models HHT-IX: FM Intrinsically Safe, Class I Div. 1 Group A, B, C, D, Class II Div. 1 Group E, F, G, Class III Div. 1 T4. Agency Approvals: FM, CE. Downloads Product Manual (PDF Download)

Technical Specifications

Relative Humidity Range 0 to 100% RH.
Temperature Range -40 to 140°F (-40 to 60°C).
Accuracy ±2% 10 to 90% RH, ±0.9°F at 72°F (±0.3°C at 25°C).
Hysteresis ±1%.
Repeatability ±0.1% typical.
Temperature Limits -40 to 140°F (-40 to 60°C).
Storage Temperature -40 to 176°F (-40 to 80°C).
Compensated Temperature -40 to 140°F (-40 to 60°C).
Power Requirements For intrinsically safe models HHT-IX, 9.5 to 28 VDC. For explosion-proof models HHT-EX, 16.5 to 28 VDC.
Output Signal 4 to 20 mA
Response Time 15 electrical
Connections Screw terminal block.
Conduit Connection 1/2" female
Updrift <1% RH/year.
RH Sensor Capacitance polymer.
Temperature Sensor Solid state band gap.
Housing Material Aluminum.
Display Optional 2 line alpha numeric, 8 characters/line.
Display Resolution RH: 0.1%;
Temperature 0.1°F (0.1°C).Weight:2 lb 8 oz (1134 g).