Home
→
Departments
→
Mechanical
→
Liquid Cooling
→
Gauges
→
Level Switches & Transmitters
→
DWYER Series CRF2 Capacitive Level Transmitter w/Rod Probe, 3/4" MNPT DWYR9X
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Dwyer
MFR#
DWYR9X
DWYER Series CRF2 Capacitive Level Transmitter w/Rod Probe, 3/4" MNPT DWYR9X
Service
Liquids, powders, and bulk materials compatible with wetted materials.
Wetted Materials
Standard: rod/cable: FEP; connection: 316 SS.
Ground Option
rod/cable and connection: 316 SS; cable spacers: PVC.
Flange Option
material of flange.
Search Similar Products
Uncheck any specs you want to ignore
Description
The Series CRF2 is a level transmitter providing a two-wire 4 to 20 mA output to indicate level of liquids, powders and bulk materials. State of the art sensing technology in the CRF2, using impulse RF admittance measurement provides excellent accuracy and stability. The CRF2 senses capacitance changes resulting from the height of the material in the tank between the probe and the tank wall. In non-metallic tanks or tanks that do not have the wall parallel to the probe a ground reference must be used. The CRF2 comes with either a rigid or flexible probe depending on application installation need and probe length required. Featured in the CRF2 is easy push button calibration of zero and span. Custom order the CRF2 to any length probe that you need for your application. FEP covered probe is ideal for use with corrosive media. This technology also provides immunity to external RF sources like walkie-talkies and cell phones as well as minimal interference with radio communication or other electronic systems. Applications: Pulp & Chemical Processing, Food & Beverage, Aggregates, Plastics, Mining. Features State of the art sensing technology, uses impulse RF admittance measurement which provides excellent accuracy and stability Comes with either a rigid or flexible probe depending on application installation need and probe length required Easy push button calibration of zero and span Any length probe can be customer ordered for any specific application FEP covered probe is ideal for use with corrosive media Immune to external RF sources like walkie-talkies and cell phones as well as minimal interference with radio communication or other electronic systems. Specifications Service:Liquids, powders, and bulk materials compatible with wetted materials. Wetted Materials: Standard: rod/cable: FEP; connection: 316 SS. Ground Option: rod/cable and connection: 316 SS; cable spacers: PVC. Flange Option: material of flange. Capacity Range: 0 to 2000 pF. Sensitivity:0.15 pF. Minimum Span: 8 pF. Accuracy:±0.5 pF or ±0.25% of span, whichever is greater. Repeatability: ±0.25 pF or ±0.1% of span, whichever is greater. Temperature Limits: Ambient: -40 to 185°F (-40 to 85°C) Process: -40 to 250°F (-40 to 121°C). Pressure Limit:100 psi (6.9 bar). Power Requirements: 12 to 35 VDC. Output Signal: 4 to 20 mA or 20 to 4 mA, 2 wire. Response Time: 0.5 electrical Connection: Screw terminal. Conduit Connection: 1/2" NPT female. Process Connection: Standard: 3/4" NPT male. Enclosure Rating 4X (IP66) weather tight/corrosion resistant. Spark/Static Protection: 106 ohm dissipation resistance with spark gap. Surge current to 100 A max. Calibration: Zero, Span, 4 mA, 20 mA. Mounting Orientation: Vertical. Weight: 6' rod type: 3.6 lb (1.63 kg). Downloads Product Manual (PDF Download)
Technical Specifications
Service
Liquids, powders, and bulk materials compatible with wetted materials.
Wetted Materials
Standard: rod/cable: FEP; connection: 316 SS.
Ground Option
rod/cable and connection: 316 SS; cable spacers: PVC.
Flange Option
material of flange.
Capacity Range
0 to 2000 pF.
Sensitivity
0.15 pF.
Minimum Span
8 pF.
Accuracy
±0.5 pF or ±0.25% of span, whichever is greater.
Repeatability
±0.25 pF or ±0.1% of span, whichever is greater.
Temperature Limits
Ambient: -40 to 185°F (-40 to 85°C)
Process
-40 to 250°F (-40 to 121°C).
Pressure Limit
100 psi (6.9 bar).
Power Requirements
12 to 35 VDC.
Output Signal
4 to 20 mA or 20 to 4 mA, 2 wire.
Response Time
0.5 electrical
Connection
Screw terminal.
Conduit Connection
1/2" NPT female.
Process Connection
Standard: 3/4" NPT male.
Spark/Static Protection
106 ohm dissipation resistance with spark gap.
Calibration
Zero, Span, 4 mA, 20 mA.
Similar Products
Flowline
FLOWLINE EchoPod® DL14 Ultrasonic Multi-Function Liquid Level Sensor, 1 in. NPT, 4.1 ft. Range DL14-00
DL14-00
Flowline
FLOWLINE USB FOB for WebCal Sensor Configuration LI99-2001
LI99-2001
Flowline
FLOWLINE EchoTouch® US01 & US03 Reflective Ultrasonic Non-Contact Liquid Level Sensor Transmitter, 2 in. NPT, Intrinsically Safe US01-0001-00
US01-0001-00
Flowline
FLOWLINE DataLoop® LI23 Level Sensor Indicator & Display with Alarms w/ 2 Relays, 4-20mA Repeater LI23-1211
LI23-1211
Flowline
FLOWLINE Switch-Tek® LV42 Large Sump Float Level Switch SPDT 10 (3) A 250V, 20 ft. cable LV42-7201
LV42-7201
Flowline
FLOWLINE Switch-Tek® LV41 Small Sump Float Level Switch, SPDT 10 (8) A 250V, w/ 20 ft. Cable LV41-7201
LV41-7201
Flowline
FLOWLINE EchoTouch® US06 Reflective Ultrasonic Liquid Level Sensor Transmitter, 19.6 Ft. Range, 2 in. NPT, Intrinsically Safe US06-0001-00
US06-0001-00
Flowline
FLOWLINE EchoPod® DL24 Ultrasonic Multi-Function Liquid Level Sensor Transmitter, 1 in. NPT, 9.8 ft. Range DL24-00
DL24-00
Can't find it?
We source what you need.