DWYER Series CLS2 Capacitive Level Switch, Waterproof w/Probe DWYR60X
Service
Liquids, powder and bulk materials compatible with wetted materials.
Wetted Materials
316 SS and polyvinylidene fluoride (PVDF).
Temperature Limits
Ambient: -40 to 185°F (-40 to 85°C), -4 to 185°F (-20 to 85°C) with under 24 VAC/DC power supply
Process
-40 to 250°F (-40 to 121°C).
Search Similar Products
Uncheck any specs you want to ignore
Description
The CLS2 is a capacitive technology level switch that does not have any moving parts - no jams, no wear, nothing to break, and no maintenance. State of the art sensing technology in the CLS2, using impulse RF admittance measurement combined with an active guard, provides excellent level measurement and stability while being insensitive to material buildup. This technology also provides immunity to external RF sources like walkie-talkies and cell phones as well as minimal interference with radio communication or other electronic systems. Capacitive level technology can be used for liquids, powders and bulk materials and is great for difficult applications such as slurries, coating products, and liquids and solids. The CLS2 is ideal for level indication in silos, receivers, and transporters in pneumatic conveying systems. The CLS2 can also be used for liquid interface applications to detect the level of two immiscible liquids that have different dielectric constants such as oil and water. Wetted materials of PVDF and 316 SS assure great chemical compatibility and meet food grade requirements. Applications: Boilers & Steam generators, Food & Beverage, Caustics & Acids, Pharmaceuticals, Sumps, Level indication in Silos. Features Automatic Calibration: No need to turn calibration pots, just push the calibration button. The CLS2 even has an external magnet to activate the calibration without having to open the enclosure. Universal Power Supply: One model works from 12 to 240 VAC/DC without any jumpers or settings. Coat Guard: Unit is not affected by sticky, dusty, or clingy materials that coat or build up on the probe preventing false alarms. Failsafe Setting: Output switches can be set for Normally Open or Normally Closed condition on loss of power. Status Indication: Ultra high brightness external red LED switch status indicator, and internal indicators for power, sensor, and switch status that can be seen externally with window cap option (external LED on weatherproof model only). Time Delay: Prevent false alarms from material splashing, agitation, etc. Removable Terminals: Removable terminal block snaps in and out enabling easy wiring outside of the enclosure. No Moving Parts: Permitting for no jams, no wear, nothing to break, and no maintenance. Impulse RF: Admittance measurement combined with an active guard, provides excellent level measurement and stability while being insensitive to material buildup. Immune To: External RF sources like walkie-talkies and cell phones as well as minimal interference with radio communication or other electronic systems. Can Be Used For: Liquid interface applications to detect the level of two immiscible liquids that have different dielectric constants such as oil and water. Wetted Materials: PVDF and 316 SS assure great chemical compatibility and meet food grade requirements. /ul> Specifications Service: Liquids, powder and bulk materials compatible with wetted materials. Wetted Materials:316 SS and polyvinylidene fluoride (PVDF). Temperature Limits: Ambient: -40 to 185°F (-40 to 85°C), -4 to 185°F (-20 to 85°C) with under 24 VAC/DC power supply Process: -40 to 250°F (-40 to 121°C). Pressure Limit: 365 psi (25 bar). Enclosure Rating: Weatherproof, NEMA 4X. Switch Type: DPDT (two form C). Electrical Rating:8 A @ 120/240 VAC res., 30 VDC. 1/2 hp @ 120 VAC and 1/4 hp @ 240 VAC ind. Power Requirements: 12 to 240 VAC/DC. Power Consumption: 2.8 Watts max. Electric Connections: 1/2" NPT conduit opening, screw termination and removable terminal block. Process Connection: See Catalog Page. Mounting Orientation: Vertical or horizontal. Set Point Adjustment: Trips when product touches probe. Cut or extend probe to length of desired trip point. Can be cut as short a 1" and can be extended by welding on to probe. (Minimum length will be effected by material being sensed.) Response Time:0.2 s. Time Delay: Adjustable, 0 to 60 s. Spark/Static Protection: 10 MEG…
Technical Specifications
Service
Liquids, powder and bulk materials compatible with wetted materials.
Wetted Materials
316 SS and polyvinylidene fluoride (PVDF).
Temperature Limits
Ambient: -40 to 185°F (-40 to 85°C), -4 to 185°F (-20 to 85°C) with under 24 VAC/DC power supply
Process
-40 to 250°F (-40 to 121°C).
Pressure Limit
365 psi (25 bar).
Enclosure Rating
Weatherproof, NEMA 4X.
Switch Type
DPDT (two form C).
Electrical Rating
8 A @ 120/240 VAC res., 30 VDC. 1/2 hp @ 120 VAC and 1/4 hp @ 240 VAC ind.
Power Requirements
12 to 240 VAC/DC.
Power Consumption
2.8 Watts max.
Electric Connections
1/2" NPT conduit opening, screw termination and removable terminal block.
Process Connection
See Catalog Page.
Mounting Orientation
Vertical or horizontal.
Set Point Adjustment
Trips when product touches probe. Cut or extend probe to length of desired trip point. Can be cut as short a 1" and can be extended by welding on to probe. (Minimum length will be effected by material being sensed.)
Response Time
0.2 s.
Time Delay
Adjustable, 0 to 60 s.
Spark/Static Protection
10 MEG Ohm dissipation resistance with spark gap.
Sensitivity
8 selectable settings, 1, 2, 4, 6, 8, 10, 14, 20 pF (at 30 pF nominal free capacitance)
SKU
Please choose an option below
Manufacturer
Dwyer
Similar Products
Flowline
FLOWLINE EchoPod® DL14 Ultrasonic Multi-Function Liquid Level Sensor, 1 in. NPT, 4.1 ft. Range DL14-00
DL14-00
Flowline
FLOWLINE USB FOB for WebCal Sensor Configuration LI99-2001
LI99-2001
Flowline
FLOWLINE EchoTouch® US01 & US03 Reflective Ultrasonic Non-Contact Liquid Level Sensor Transmitter, 2 in. NPT, Intrinsically Safe US01-0001-00
US01-0001-00
Flowline
FLOWLINE DataLoop® LI23 Level Sensor Indicator & Display with Alarms w/ 2 Relays, 4-20mA Repeater LI23-1211
LI23-1211
Flowline
FLOWLINE Switch-Tek® LV42 Large Sump Float Level Switch SPDT 10 (3) A 250V, 20 ft. cable LV42-7201
LV42-7201
Flowline
FLOWLINE Switch-Tek® LV41 Small Sump Float Level Switch, SPDT 10 (8) A 250V, w/ 20 ft. Cable LV41-7201
LV41-7201
Flowline
FLOWLINE EchoTouch® US06 Reflective Ultrasonic Liquid Level Sensor Transmitter, 19.6 Ft. Range, 2 in. NPT, Intrinsically Safe US06-0001-00
US06-0001-00
Flowline
FLOWLINE EchoPod® DL24 Ultrasonic Multi-Function Liquid Level Sensor Transmitter, 1 in. NPT, 9.8 ft. Range DL24-00
DL24-00
Can't find it?
We source what you need.