Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Mechanical → Industrial → Safety → Gas Detectors & Accessories → OTIS INSTRUMENTS OI-6000 Series Explosion Proof Wired Powered Ambient Air Hazardous Gas Detector OI-6000-X-X-X-X-O
OTIS INSTRUMENTS OI-6000 Series Explosion Proof Wired Powered Ambient Air Hazardous Gas Detector OI-6000-X-X-X-X-O
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Otis Instruments
MFR# OI-6000-X-X-X-X-O

OTIS INSTRUMENTS OI-6000 Series Explosion Proof Wired Powered Ambient Air Hazardous Gas Detector OI-6000-X-X-X-X-O

Sensor Type Electrochemical, Infrared, Catalytic Bead or PID - Dependent on Gas Type
Operating Voltage Wired Powered (3-Wire) 12 to 35 VDC
Power Draw 2 Watts Maximum
Display Screen 102x64 Resolution Graphical LCD Screen; Transflective (Sunlight Readable) with White LED Backlight

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The Otis Instruments OI-6000 Series Ambient Air Hazardous Gas Detector is a versatile assembly that uses an electrochemical, infrared, catalytic bead or PID sensor element to detect a variety of gases. Wired powered (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs standard. Magnetic switches allow for non-intrusive calibration while in the field as well as full system settings and diagnostics. Note: The OI-6000 unit can be customized to detect a variety of gases. See the "Gas Chart" tab for the full list of gases. Please call 1-800-333-3331 for more information. Options: Additional radio and relay options are available. Please call 1-800-333-3331 for more information. Features Electrochemical, Infrared, Catalytic Bead or PID Sensor Element - Dependent on Gas Type Wired Powered (3-Wire), 12 to 35 VDC Operating Voltage Operating Temperature Range of -40°C to +54°C (-40°F to 129.2°F) Graphical LCD with LED Backlight 3 Push-Button Interface (ADD, MENU, SUB) with 3 Corresponding Magnetic, Non-Intrusive Switches 2 Individually Configurable Alarm Set Points: Two Front Panel LED Indicators (Amber and Red); Optional 2 Dry-Contact Relays Output Options: 4-20 mA (3-Wire) Analog, RS-485 Modbus, Optional GEN II 900 MHz or GEN II 2.4 GHz Radio Sensor Element Warranty Subject to Otis Verification 1-Year Limited Hardware Warranty Specifications Sensor Type: Electrochemical, Infrared, Catalytic Bead or PID - Dependent on Gas Type Operating Voltage: Wired Powered (3-Wire) 12 to 35 VDC Power Draw: 2 Watts Maximum Protection: Power Electromagnetic Interference (EMI) Filter 4-20 mA Surge Suppression RS-485 Surge Suppression Display Screen: 102x64 Resolution Graphical LCD Screen; Transflective (Sunlight Readable) with White LED Backlight Interface: 3 Push-Buttons (MENU, ADD, and SUB) 3 Magnetic, Non-Intrusive Switches for Calibration Customizable Settings: 2 Individually-Configurable Alarm LED/Relay Set-Points Tamb. Temperature Range: -40°C to +54°C (-40°F to 129.2°F) Output (Digital) RS-485 Modbus Wired (Analog) Output: 4-20 mA (3-Wire) Fault Terminal Optional 2 Dry-Contact Relays with Replaceable 4 Amp Fuses Remote Sensor Kit (Optional Additional Feature): OI-501-5 Remote Sensor Kit with Enclosure (5-Pin) Electrochemical Sensor Max. Length: 250 ft. Infrared Sensor Max. Length: 40 ft. PID Sensor Max. Length: 35 ft. Catalytic Bead Sensor Max. Length: 15 ft. Product Dimensions: 5.5 in. L x 6 in. W x 7 in. H (8 in. W x 17 in. H Max. with Attachments) Total Weight: 6 lbs. Hardware Warranty: 1-Year, Limited Sensor Element Warranty: Varies with Gas Type Hazardous Location Certifications & Approvals: CSA Class I, Division 1, Groups C & D Ex d IIB T6 Gb Class I, Zone 1, AEx db IIB T6 Gb Tamb-40°C to +54°C (-40°F to 129.2°F) ATEX Models w/ Radio Option Ex II 2 (1) G Ex db mb ia [ia Ga] IIB T6 Gb Tamb-40°C to +54°C (-40°F to 129.2°F) Models w/out Radio Option Ex II 2 G Ex db mb IIB T6 Gb Tamb-40°C to +54°C (-40°F to 129.2°F) IECEx Models w/ Antenna Fitting Ex db mb ia [ia Ga] IIB T6 Gb Tamb-40°C to +54°C (-40°F to 129.2°F) Models w/out Antenna Fitting Ex db mb IIB T6 Gb Tamb-40°C to +54°C (-40°F to 129.2°F) Gas Chart Gas TypeRangeT90Sensor TypeWarranty AsH3 - Arsine 0-1 ppm < 30 sec. Electrochemical 10 months CH2O - Formaldehyde 0-10 ppm < 30 sec. Electrochemical 12 months CH3SH - Methanethiol 0-10 ppm < 100 sec. Electrochemical 12 months CH4 - Methane 0-100% vol. < 30 sec. Infrared 60 months Cl2 - Dichlorine 0-20 ppm < 60 sec. Electrochemical 12 months ClO2 - Chlorine Dioxide 0-5 ppm < 120 sec. Electrochemical 12 months CO - Carbon Monoxide 0-1000 ppm < 30 sec. Electrochemical 24 months CO2 - Carbon Dioxide 0-5% vol. < 30 sec. Infrared 60 months ETO - Ethylene Oxide 0-10 ppm < 80 sec. Electrochemical 12 months F2 - Fluorine 0-1 ppm < 80 sec. Elect…

Technical Specifications

Sensor Type Electrochemical, Infrared, Catalytic Bead or PID - Dependent on Gas Type
Operating Voltage Wired Powered (3-Wire) 12 to 35 VDC
Power Draw 2 Watts Maximum
Display Screen 102x64 Resolution Graphical LCD Screen; Transflective (Sunlight Readable) with White LED Backlight
Customizable Settings 2 Individually-Configurable Alarm LED/Relay Set-Points
Tamb. Temperature Range -40°C to +54°C (-40°F to 129.2°F)
Electrochemical Sensor Max. Length 250 ft.
Infrared Sensor Max. Length 40 ft.
PID Sensor Max. Length 35 ft.
Catalytic Bead Sensor Max. Length 15 ft.
Product Dimensions 5.5 in. L x 6 in. W x 7 in. H (8 in. W x 17 in. H Max. with Attachments)
Total Weight 6 lbs.
Hardware Warranty 1-Year, Limited
Sensor Element Warranty Varies with Gas Type
SKU Please choose an option below
Manufacturer Otis Instruments
Weight 6.00 LBS
Can't find it?
We source what you need.
Bookmarks
Recently Viewed
Compare