OTIS INSTRUMENTS Omniguard Model 760 Aluminum Multi-Spectrum Infrared Flame Detector, Auto Self Test, Latching 760-00100
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Otis Instruments
MFR#
760-00100
OTIS INSTRUMENTS Omniguard Model 760 Aluminum Multi-Spectrum Infrared Flame Detector, Auto Self Test, Latching 760-00100
Model
Omniguard 760
Operating Temperature
-40°F to 185°F (-40°C to 85°C)
Spectral Response
Infrared Peak Sensitivities of 2.2 μm, 3.7 μm, 4.4 μm, and 5.8 μm
Nominal Voltage
24 VDC (Ripple Voltage <240mV)
Search Similar Products
Uncheck any specs you want to ignore
Description
Otis Instruments Omniguard Model 760 multi-spectrum infrared flame detector is designed to detect unwanted fires and output alarm information. The Model 760 senses infrared radiation in five discreet infrared wavelengths for early fire detection for maximum protection of people, machinery, and facilities. Utilizes the patented Omniguard Fire Event Algorithm for superior false alarm immunity and quick detection of hydrocarbon fueled fires. Otis Instrument flame detectors have an automatic self-test function to monitor the detector's ability to sense fires and report a fault condition when impaired. The self test feature also eliminates the need for any external test fixtures. Notes: Swivel mount (20856) included. Other configurations available - Please call 1-800-333-3331 for more information. Features Patented Fire Event Analysis (FEA) Algorithm for Superior False Alarm Immunity Operating Temperature: -40°F to 185°F (-40°C to 85°C) User-Selectable Sensitivities Long Range Detection Advanced Through-the-Lens Diagnostic Self-Test (No External Test Source Required) Self-Contained, Explosion-Proof Enclosure Field Configurable Relays and Sensitivity State-of-the-Art Microprocessor Control Wide Field of View of 90° High Intensity, Localized Indication of Proper Operation: Fire or Fault FM, CSA, IECEx and ATEX Approved 5-Year Warranty Specifications Model: Omniguard 760 Operating Temperature: -40°F to 185°F (-40°C to 85°C) Spectral Response: Infrared Peak Sensitivities of 2.2 μm, 3.7 μm, 4.4 μm, and 5.8 μm Nominal Voltage: 24 VDC (Ripple Voltage <240mV) Range: 20 to 30 VDC Power Consumption: 80 mA (Standby), 100 mA (Alarm), 160 mA (Auto and Manual Test) Output: Relay Relays (2): Fire, Trouble, Dry Contacts, Hermetically Sealed Rated: 2 A at 28 VDC (User Selects NO or NC) Fire Relay: Latching (Non-Latching Optional) Current Loop (Standard Version): 0 to 20 mA Output 20 mA = Fire 16 mA = Warning Fire IR 5 mA = Warning Ref IR 3 mA = Fire Relay Coil Fault 2 mA = Calibration Not Complete 1 mA = Self-Test Fault 0 mA = Current Loop Fault 4 mA = Normal Digital Output: RS-485 Modbus Serial I/O Product Dimensions: 4.5 in. H x 5.5 in. W x 4.9 in. D Total Weight: 5 lbs. Conduit Entry: 3/4-14 NPTF (M20-1.5 Optional) Optional Accessories: Portable Test Unit - Model 545 Rain Shield - No. 23546 Pole Mount for Swivel Mount - No. 26803 Certifications & Approvals Class I, Division 1, Groups B, C & D (Explosion Proof) Class II, Division 1, Groups E, F & G (Dust Ignition Proof) TYPE 4X Weatherproof, Dust-Tight, Watertight CE0081 Ex d II 2 G/D Ex d IIB+H2 T5 Gb for Gas EX tb IIIC T100°C Db IP66 for Dust Copper-Free Aluminum Housing Coated to MIL-C-5541C, Class 3 (White) Downloads Omniguard Model 760 Data Sheet (PDF Download) Omniguard Swivel Mount Data Sheet (PDF Download)
Technical Specifications
Model
Omniguard 760
Operating Temperature
-40°F to 185°F (-40°C to 85°C)
Spectral Response
Infrared Peak Sensitivities of 2.2 μm, 3.7 μm, 4.4 μm, and 5.8 μm
Nominal Voltage
24 VDC (Ripple Voltage <240mV)
Range
20 to 30 VDC
Power Consumption
80 mA (Standby), 100 mA (Alarm), 160 mA (Auto and Manual Test)
Relays (2)
Fire, Trouble, Dry Contacts, Hermetically Sealed
Rated
2 A at 28 VDC (User Selects NO or NC)
Fire Relay
Latching (Non-Latching Optional)
Current Loop (Standard Version)
0 to 20 mA Output
Digital Output
RS-485 Modbus Serial I/O
Product Dimensions
4.5 in. H x 5.5 in. W x 4.9 in. D
Total Weight
5 lbs.
Conduit Entry
3/4-14 NPTF (M20-1.5 Optional)
SKU
AOI76000100SWIV
Manufacturer
Otis Instruments
Weight
5.00 LBS
Similar Products
Otis Instruments
OTIS INSTRUMENTS Omniguard Model 860 Aluminum Ultraviolet Infrared Flame Detector, Auto Self Test, Latching 860-00100
860-00100
Otis Instruments
OTIS INSTRUMENTS Omniguard Model 660 Aluminum Ultraviolet Flame Detector, Auto Self Test, Latching 660-00100
660-00100
PIP
PIP Boss® High Performance Oil & Gas Silicone Grip Gloves, 12 Pairs/ Pack 120MP2415-M
120MP2415-M
PIP
PIP Boss® Hi-Vis High Performance Red PVC Grip Gloves, 12 Pairs/Pack 120MP2120-M
120MP2120-M
Majestic
MAJESTIC Superdex® 3237 Micro Foam Nitrile Dipped Glove, 12 Pairs/Pack MJST12X
MJST12X
UltraTech International
ULTRATECH INTERNATIONAL UltraTech Sidewinder, 34 in. L x 13 5/8 in. W x 2 1/8 in. H Cable Protection System w/Endcaps, Black and Yellow 1840
1840
Lakeside Plastics
LAKESIDE PLASTICS Perimeter Defender 42 in. OSHA Compliant Warning Line Device 39-X-X-X-X-X-XR30
39-X-X-X-X-X-XR30
Lakeside Plastics
LAKESIDE PLASTICS The Divertor 42 in. Trimline Channelizer w/ 16 lb Base LKSD5X
LKSD5X
Can't find it?
We source what you need.