Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Switches → Safety Switches → TELEMECANIQUE SENSORS Cable Pull Sw 240Vac 10A Xy2(Metric XY2CH13270
TELEMECANIQUE SENSORS Cable Pull Sw 240Vac 10A Xy2(Metric XY2CH13270
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Telemecanique Sensors
MFR# XY2CH13270

TELEMECANIQUE SENSORS Cable Pull Sw 240Vac 10A Xy2(Metric XY2CH13270

Country of Origin Morocco
Item Cable Pull Switch
Reset by booted push-button
Standards EN/ISO 13850 || machinery directive 2006/42/EC || EN/IEC 60947-5-1 || EN/IEC 60947-5-5 || work equipment directive 2009/104/EC || EN/IEC 60204-1

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Cable Pull Switch

Technical Specifications

Country of Origin Morocco
Item Cable Pull Switch
Reset by booted push-button
Standards EN/ISO 13850 || machinery directive 2006/42/EC || EN/IEC 60947-5-1 || EN/IEC 60947-5-5 || work equipment directive 2009/104/EC || EN/IEC 60204-1
Body Material zamak
Series XY2CE
Safety Level can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Mechanical Durability 800000 cycles
Local Signalling without pilot light
Cover Material stainless steel
Product Or Component Type latching emergency stop rope pull switch
Tightening Torque 0.8-1.2 N.m
Distance Between Cable Supports 5-5 m
Marking CE
Contacts Type And Composition 2 NC
Terminals Description Iso N°1 (21-22)NC || (11-22)NC
Compatibility Code XY2CH
Device Short Name XY2CH
Maximum Resistance Across Terminals 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Ip Degree Of Protection IP65 IEC 60529
Product Certifications UL category NISD emergency stop devices || CCC
Overvoltage Category class I EN/IEC 61140 || class I NF C 20-030
[Ui] Rated Insulation Voltage 500 V 3)EN/IEC 60947-1 || 300 VUL 508
Protective Treatment TC
Connections - Terminals screw clamp terminal, 1 x 0.5 to 2 x 1.5 mm²
Housing Colour red RAL 3000
Short-Circuit Protection 10 A cartridge fuse gG EN/IEC 60269
[Ithe] Conventional Enclosed Thermal Current 10 A
Trigger Cable Anchor Point RH or LH side
Cable Entry Number 3 tapped entry Pg 13.5 cable gland
Can't find it?