Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Switches
→
Limit Switches & Accessories
→
TELEMECANIQUE SENSORS Limit Switch Lever Arm ZCKM1H29
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Telemecanique Sensors
MFR#
ZCKM1H29
TELEMECANIQUE SENSORS Limit Switch Lever Arm ZCKM1H29
Country of Origin
Indonesia
Item
Limit Switch Lever Arm
Ambient Air Temperature For Storage
-40-70°C
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Search Similar Products
Uncheck any specs you want to ignore
Description
Limit Switch Lever Arm
Technical Specifications
Country of Origin
Indonesia
Item
Limit Switch Lever Arm
Ambient Air Temperature For Storage
-40-70°C
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Product Compatibility
XCKM
Maximum Resistance Across Terminals
0.25 mOhm IEC 60255-7 category 3
Number Of Steps
1 1 position
Ambient Air Temperature For Operation
-25-70°C standard environment
Number Of Poles
2
Electrical Durability
5000000 cycles, DC-13 120 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 24 V, 13 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13 48 V, 9 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
Body Type
fixed
Positive Opening
with
Electrical Connection
screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Ip Degree Of Protection
IP66
Product Or Component Type
limit switch body
Series Name
standard format
[Ithe] Conventional Enclosed Thermal Current
10A
Contacts Type And Composition
1 NC + 1 NO
Body Material
metal
Short-Circuit Protection
10 A cartridge fuse gG
Contact Operation
snap action
Device Short Name
ZCKM
Associated Head
ZCKD06 || ZCKD16 || ZCKD219 || ZCKD08 || ZCKD21 || ZCKD05 || ZCKD81 || ZCKD23 || ZCKD239 || ZCKD10 || ZCKD41 || ZCKD15 || ZCKD029 || ZCKD59 || ZCKD02 || ZCKD17 || ZCKD109 || ZCKD91
[Ui] Rated Insulation Voltage
500 V 3)IEC 60947-1 contact block || 300 VCSA C22.2 No 14 contact block || 300 VUL 508 contact block
Minimum Actuation Speed
0.01 m/min
Cable Entry
3 entries tapped for M20 x 1.5 cable gland
Contacts Material
silver plated contacts
Environmental Characteristic
standard environment
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
Similar Products
Telemecanique Sensors
TELEMECANIQUE SENSORS Heavy Duty Limit Switch, No Lever, Rotary, 1NC/1NO, 10A at 600V AC, CCW/CW 9007C54B2
9007C54B2
Telemecanique Sensors
TELEMECANIQUE SENSORS RodLeverActuator, StainlessSteel, 10inArmL 9007FA1
9007FA1
Telemecanique Sensors
TELEMECANIQUE SENSORS Heavy Duty Limit Switch, No Lever, Rotary, 2NC/2NO, 10A at 600V AC, CCW/CW 9007C62B2
9007C62B2
Omron
OMRON Limit Switch, Plunger, SPDT, 15A at 480V AC, Actuator Location: Top ZE-N-2S
ZE-N-2S
Omron
OMRON Limit Switch, Coil Spring, Wobble Stick, SPDT, 15A at 480V AC, Actuator Location: Top ZE-NJ-2S
ZE-NJ-2S
Telemecanique Sensors
TELEMECANIQUE SENSORS LmtSwtchLvrArm, RotryLvrRollr, Adj, 4inArmL 9007HA1
9007HA1
Telemecanique Sensors
TELEMECANIQUE SENSORS LmtSwtchLvrArm, RotaryLvrRoller, 1.5inArmL 9007MA11
9007MA11
Telemecanique Sensors
TELEMECANIQUE SENSORS Limit Switch, Plug In, Rotary Head, 10 A at 600V AC, 2NO/2NC, No Actuator Included 9007C68T10
9007C68T10
Can't find it?
We source what you need.