Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Programmable Logic Controls (PLC) → Programmable Logic Controllers → SCHNEIDER ELECTRIC Compact Smart Relay, 12Inputs, 4Outputs SR2B121BD
SCHNEIDER ELECTRIC Compact Smart Relay, 12Inputs, 4Outputs SR2B121BD
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# SR2B121BD

SCHNEIDER ELECTRIC Compact Smart Relay, 12Inputs, 4Outputs SR2B121BD

Country of Origin Indonesia
Item Compact Smart Relay
Output Type (4) Relay
Number of Outputs 4

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Compact Smart Relay, Input Voltage 24V AC/DC, Output Type (4) Relay, 8 A Amps, Number of Inputs 12, Number of Outputs 4, Counters 16, Timers 16, Yes Clock, LCD Display, Depth 2.34 in, Height 4.24 in, Width 2.8 in

Technical Specifications

Country of Origin Indonesia
Item Compact Smart Relay
Output Type (4) Relay
Number of Outputs 4
Number of Inputs 12
Features Compact Design, Malfunctions Diagnosing Display, Simple Programming
Input Voltage 24V AC, 24V DC
Clock Yes
Display LCD
Amps 8 A
Timers 16
Counters 16
Standards EN/IEC 61000-4-12 || EN/IEC 61000-4-4 level 3 || EN/IEC 61000-4-5 || EN/IEC 61000-4-11 || EN/IEC 61000-4-2 level 3 || EN/IEC 60068-2-6 Fc || EN/IEC 61000-4-6 level 3 || EN/IEC 60068-2-27 Ea || EN/IEC 61000-4-3
Response Time 10 ms from state 0 to state 1)relay output || 5 ms from state 1 to state 0)relay output
Product Type Compact Smart Relay
Reverse Polarity Protection with
Discrete Input Voltage 24 V DC
Ip Degree Of Protection IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Pollution Degree 2 EN/IEC 61131-2
Lsb Value 39 mV analogue input circuit
Current State 1 Guaranteed >= 1.2 mA IB to IG used as discrete input circuit) || >= 2.2 mA I1 to IA and IH to IR discrete input circuit)
Number Or Control Scheme Lines 0-240 ladder || 0-500 FBD
Analogue Input Resolution 8 bits
Ambient Air Temperature For Operation -20-40 °C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55 °C IEC 60068-2-1 and IEC 60068-2-2
Conversion Time smart relay cycle time analogue input circuit
Voltage State 0 Guaranteed <= 5 V I1 to IA and IH to IR discrete input circuit || <= 5 V IB to IG used as discrete input circuit
Clock Drift 12 min/year 0-55 °C || 6 s/month 25-25 °C
Repeat Accuracy +/- 2 % 55 °C analogue input circuit
Temperature Probe Type NTC 10k 25 °C || NTC 1000k 25 °C || KTY81 210/220/221/222/250 || Pt 500
Relative Humidity 95-95 % without condensation or dripping water
Can't find it?
We source what you need.
Bookmarks
Recently Viewed
Compare