Brand Schneider Electric
MFR# SR3XT101FU

SCHNEIDER ELECTRIC Discrete I/O Module, 6 Inputs, 4 Outputs SR3XT101FU

Country of Origin Korea, Republic of
Item Discrete Input/Output Module
Power Required 100 to 240V AC
Number of Inputs 6

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Discrete Input/Output Module, Number of Inputs 6, For Use With SR3B Logic Relays, Number of Outputs 4, Power Required 100 to 240V AC, Features Zelio Logic Programming, Product Type Extension Module, Current Rating 0.6 mA, Mounting Style DIN Rail, Wire Connection Type Screw Clamp

Technical Specifications

Country of Origin Korea, Republic of
Item Discrete Input/Output Module
Power Required 100 to 240V AC
Number of Inputs 6
Number of Outputs 4
For Use With SR3B, SR3XT
Includes Instruction Manual
Features Zelio Logic Programming
Product Type Discrete Input/Output Module
Output Type (4) Relay
Standards EN/IEC 60068-2-27 Ea || EN/IEC 61000-4-12 || EN/IEC 61000-4-3 || EN/IEC 61000-4-2 level 3 || EN/IEC 61000-4-5 || EN/IEC 61000-4-6 level 3 || EN/IEC 60068-2-6 Fc || EN/IEC 61000-4-11 || EN/IEC 61000-4-4 level 3
Ambient Air Temperature For Operation -20-40°C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55°C IEC 60068-2-1 and IEC 60068-2-2
Cycle Time 6-90 ms
Operating Rate In Hz 0.1 Hz at Ie)relay output || 10 Hz no load)relay output
Operating Altitude 6561.68 ft (2000 m)
[Uimp] Rated Impulse Withstand Voltage 4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Ip Degree Of Protection IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Discrete Input Number 6
[Us] Rated Supply Voltage 100 to 240 V AC
Environmental Characteristic EMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
Maximum Altitude Transport 3048 m
Clock Drift 12 min/year 0-55°C
Voltage State 1 Guaranteed >= 79 V discrete input
Electrical Durability AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1
Reverse Polarity Protection with
Product Or Component Type discrete I/O extension module
Voltage State 0 Guaranteed <= 40 V discrete input
Supply Voltage Limits 85-264 V
Backup Time 10 years 25°C
Mechanical Durability 10000000 cycles relay output