Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Programmable Logic Controls (PLC)
→
Programmable Controller Accessories
→
SCHNEIDER ELECTRIC Discrete I/O Module, 6 Inputs, 4 Outputs SR3XT101FU
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Schneider Electric
MFR#
SR3XT101FU
SCHNEIDER ELECTRIC Discrete I/O Module, 6 Inputs, 4 Outputs SR3XT101FU
Country of Origin
Korea, Republic of
Item
Discrete Input/Output Module
Power Required
100 to 240V AC
Number of Inputs
6
Search Similar Products
Uncheck any specs you want to ignore
Description
Discrete Input/Output Module, Number of Inputs 6, For Use With SR3B Logic Relays, Number of Outputs 4, Power Required 100 to 240V AC, Features Zelio Logic Programming, Product Type Extension Module, Current Rating 0.6 mA, Mounting Style DIN Rail, Wire Connection Type Screw Clamp
Technical Specifications
Country of Origin
Korea, Republic of
Item
Discrete Input/Output Module
Power Required
100 to 240V AC
Number of Inputs
6
Number of Outputs
4
For Use With
SR3B, SR3XT
Includes
Instruction Manual
Features
Zelio Logic Programming
Product Type
Discrete Input/Output Module
Output Type
(4) Relay
Standards
EN/IEC 60068-2-27 Ea || EN/IEC 61000-4-12 || EN/IEC 61000-4-3 || EN/IEC 61000-4-2 level 3 || EN/IEC 61000-4-5 || EN/IEC 61000-4-6 level 3 || EN/IEC 60068-2-6 Fc || EN/IEC 61000-4-11 || EN/IEC 61000-4-4 level 3
Ambient Air Temperature For Operation
-20-40°C in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2 || -20-55°C IEC 60068-2-1 and IEC 60068-2-2
Cycle Time
6-90 ms
Operating Rate In Hz
0.1 Hz at Ie)relay output || 10 Hz no load)relay output
Operating Altitude
6561.68 ft (2000 m)
[Uimp] Rated Impulse Withstand Voltage
4 kV EN/IEC 60947-1 and EN/IEC 60664-1
Ip Degree Of Protection
IP20 IEC 60529 terminal block) || IP40 IEC 60529 front panel)
Discrete Input Number
6
[Us] Rated Supply Voltage
100 to 240 V AC
Environmental Characteristic
EMC directive EN/IEC 61000-6-2 || EMC directive EN/IEC 61000-6-3 || EMC directive EN/IEC 61000-6-4 || EMC directive EN/IEC 61131-2 zone B || low voltage directive EN/IEC 61131-2
Maximum Altitude Transport
3048 m
Clock Drift
12 min/year 0-55°C
Voltage State 1 Guaranteed
>= 79 V discrete input
Electrical Durability
AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1 || AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1 || DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1 || DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1
Reverse Polarity Protection
with
Product Or Component Type
discrete I/O extension module
Voltage State 0 Guaranteed
<= 40 V discrete input
Supply Voltage Limits
85-264 V
Backup Time
10 years 25°C
Mechanical Durability
10000000 cycles relay output
Similar Products
Schneider Electric
SCHNEIDER ELECTRIC Connecting Cable, PC USB to Relay SR2USB01
SR2USB01
Asi
ASI Mounting Receptacle, 120 V IMACP02
IMACP02
Ifm
IFM IO-Link Configuration Kit, 1 m Cable L ZZ1060
ZZ1060
Schneider Electric
SCHNEIDER ELECTRIC Tightening Tool, For M221, SCU, XB5 ZB5AZ905
ZB5AZ905
Bea
BEA Logic Module, 3-Relay, Lexan 10BR3-X
10BR3-X
Schneider Electric
SCHNEIDER ELECTRIC Memory Cartridge, EEPROM SR2MEM02
SR2MEM02
Advantech
ADVANTECH Industrial Raspberry Pi 4 HAT Gateway Kit with PoE Function UNO-220-P4N2AE
UNO-220-P4N2AE
Schneider Electric
SCHNEIDER ELECTRIC Ext Module, TM3, 8 inputs, 24VDC, 0 outputs TM3AI8
TM3AI8
Can't find it?
We source what you need.