Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Electrical Controls
→
Motor Starters, Enclosures & Accessories
→
SCHNEIDER ELECTRIC Stdcntrlunitcl103Ph 312A 24Vac LUCA12B
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Schneider Electric
MFR#
LUCA12B
SCHNEIDER ELECTRIC Stdcntrlunitcl103Ph 312A 24Vac LUCA12B
Country of Origin
Korea, Republic of
Item
Motor Starter Control Unit
Coil Voltage
24V AC
Standards
EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier; CE; CCC; EAC; ASEFA; ATEX; Marine
Search Similar Products
Uncheck any specs you want to ignore
Description
Stdcntrlunitcl103Ph 312A 24Vac
Technical Specifications
Country of Origin
Korea, Republic of
Item
Motor Starter Control Unit
Coil Voltage
24V AC
Standards
EN 60947-6-2; IEC 60947-6-2; UL 60947-4-1, with phase barrier; CSA C22.2 No 60947-4-1, with phase barrier; CE; CCC; EAC; ASEFA; ATEX; Marine
Features
Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Manual reset; Earth fault protection; Free of Halogen, Mercury & Pvc; Resistance to Fire, Electrostatic Discharge, Fast Transients, Radiated Fields, Shock & Vibration
Weight
0.135 kg
Operating Voltage
690V AC
Shock Resistance
10 gn power poles open IEC 60068-2-27; 15 gn power poles closed IEC 60068-2-27
Vibration Resistance
2 gn 5 to 300 Hz power poles open IEC 60068-2-6; 4 gn 5 to 300 Hz power poles closed IEC 60068-2-6
Resistance To Electrostatic Discharge
8 kV 3 in open air IEC 61000-4-2; 8 kV 4 on contact IEC 61000-4-2
Operating Time
35 ms opening with LUB12 control circuit; 35 ms opening with LUB32 control circuit; 35 ms opening with LUB38 control circuit; 70 ms closing with LUB12 control circuit; 70 ms closing with LUB32 control circuit; 70 ms closing with LUB38 control circuit
Thermal Overload Class
Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) IEC 60947-6-2; Class 10 40 to 60 Hz -13 to 158°F (-25 to 70°C) UL 508
Rated Insulation Voltage
690 V IEC 60947-6-2; 600 V UL 60947-4-1; 600 V CSA C22.2 No 60947-4-1
Ambient Air Temperature For Storage
-40 to 185°F (-40 to 85°C)
Motor Power KW
5.5 kW 400 to 440 V AC 50/60 Hz; 5.5 kW 500 V AC 50/60 Hz; 9 kW 690 V AC 50/60 Hz
Non-Dissipating Shock Wave
1 kV serial mode IEC 60947-6-2; 2 kV common mode IEC 60947-6-2
Immunity To Voltage Dips
70% / 500 ms IEC 61000-4-11
Control Circuit Voltage
24 V AC
Control Circuit Voltage Limits
20 to 26.5 V AC 24 V in operation; 14.5 V AC 24 V drop-out
Safe Separation Of Circuit
400 V SELV between the control and auxiliary circuits IEC 60947-1; 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Product Name
TeSys Ultra
Typical Current Consumption
140 mA 24 V AC I maximum while closing with LUB12; 220 mA 24 V AC I maximum while closing with LUB32; 220 mA 24 V AC I maximum while closing with LUB38; 70 mA 24 V AC I rms sealed with LUB12; 90 mA 24 V AC I rms sealed with LUB32; 90 mA 24 V AC I rms sealed with LUB38
Main Function Available
Protection against phase failure and phase imbalance; Protection against overload and short-circuit; Manual reset; Earth fault protection
Compatibility Code
LUCA
Rated Impulse Withstand Voltage
6 kV IEC 60947-6-2
IP Degree Of Protection
IP20 front panel and wired terminals IEC 60947-1; IP20 other faces IEC 60947-1; IP40 front panel outside connection zone IEC 60947-1
Immunity To Microbreaks
3 ms
Fire Resistance
1760°F (960°C) parts supporting live components IEC 60695-2-12; 1202°F (650°C) IEC 60695-2-12
Utilisation Category
AC-44; AC-41; AC-43
Resistance To Fast Transients
2 kV 3 serial link IEC 61000-4-4; 4 kV 4 all circuits except for serial link IEC 61000-4-4
Similar Products
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, No Enclosure NEMA Rating, 208 to 240V AC 8911DPSO13V09
8911DPSO13V09
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, No Enclosure NEMA Rating, 120V AC, 3 Poles 8911DPSO33V02
8911DPSO33V02
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, No Enclosure NEMA Rating, 208 to 240V AC 8911DPSO32V09
8911DPSO32V09
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, 1 NEMA Rating, 208 to 240V AC, 2 Poles 8911DPSG42V09
8911DPSG42V09
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, No Enclosure NEMA Rating, 208 to 240V AC 8911DPSO42V09
8911DPSO42V09
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, No Enclosure NEMA Rating, 24V AC, 3 Poles 8911DPSO43V14
8911DPSO43V14
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, No Enclosure NEMA Rating, 208 to 240V AC 8911DPSO53V09
8911DPSO53V09
Square D
SQUARE D Nonreversing Definite Purpose Magnetic Motor Starter, 1 NEMA Rating, 208 to 240V AC, 3 Poles 8911DPSG13V09
8911DPSG13V09
Can't find it?
We source what you need.