Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Motor Overload Relays → SCHNEIDER ELECTRIC Solid State O/Load Relay 575Vac 100A LR9D5567
SCHNEIDER ELECTRIC Solid State O/Load Relay 575Vac 100A LR9D5567
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LR9D5567

SCHNEIDER ELECTRIC Solid State O/Load Relay 575Vac 100A LR9D5567

Country of Origin Korea, Republic of
Item Overload Relay
Auxiliary Contact Form 1NC/1NO
Minimum Overload Relay Current Setting 60 A

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Solid State O/Load Relay 575Vac 100A

Technical Specifications

Country of Origin Korea, Republic of
Item Overload Relay
Auxiliary Contact Form 1NC/1NO
Minimum Overload Relay Current Setting 60 A
Maximum Overload Relay Current Setting 100 A
Trip Class 20
Overload Protection Type Electronic
Maximum Voltage Rating 1,000V
Standards EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || UL 60947-5-1 || CSA C22.2 No 60947-4-1 || CSA C22.2 No 60947-5-1 || GB/T 14048.4 || GB/T 14048.5
Product Or Component Type electronic thermal overload relay
Ambient Air Temperature For Operation -20-60°C without derating IEC 60947-4-1
Thermal Protection Adjustment Range 60-100 A
Product Compatibility LC1D150 || NSX circuit breaker || LC1D115
Ambient Air Temperature For Storage -60-70°C
Control Type Red push-button stop || Blue push-button reset
Dielectric Strength 1.89 kV 50 Hz IEC 60947-1
Switching Capacity In Ma 0 to 150 mA
Mechanical Robustness vibrations2 Gn, 5 to 300 Hz IEC 60068-2-6 || shocks13 Gn for 11 ms IEC 60068-2-7
Product Certifications UL || CSA || CCC || UKCA
Relay Application motor protection
Maximum Voltage Drop <2.5 V closed state
Phase Failure Sensitivity tripping in 4 s +/- 20 % IEC 60947-4-1
Signalling Function alarm
Connections - Terminals power circuit bars || control circuit screw clamp terminals 1 0.5-1.5 mm² flexible without cable end || control circuit screw clamp terminals 2 0.5-1.5 mm² flexible without cable end || alarm circuit screw clamp terminals 1 0.5-1.5 mm² flexible without cable end
Tightening Torque alarm circuit 0.45 N.m screw clamp terminals || power circuit 18 N.m bars M8 || control circuit 1.2 N.m screw clamp terminals
Network Frequency 50-60 Hz
Device Short Name LR9D
Network Type AC
Range TeSys
Climatic Withstand IACS E10