Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Electrical Controls
→
Motor Overload Relays
→
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 5.5 A Min current, 8 A Max current, 690V AC LRD12
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Schneider Electric
MFR#
LRD12
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 5.5 A Min current, 8 A Max current, 690V AC LRD12
Country of Origin
Korea, Republic of
Item
Overload Relay
Auxiliary Contact Form
1NC/1NO
Minimum Overload Relay Current Setting
5.5 A
Search Similar Products
Uncheck any specs you want to ignore
Description
TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 9 amp through 38 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 5.5 to 8 amperes. This trip current rating is calibrated per Class 10A. Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).
Technical Specifications
Country of Origin
Korea, Republic of
Item
Overload Relay
Auxiliary Contact Form
1NC/1NO
Minimum Overload Relay Current Setting
5.5 A
Maximum Overload Relay Current Setting
8:00 AM
Trip Class
10A
Overload Protection Type
Thermal
Maximum Voltage Rating
690V AC
Standards
CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, REACH, RoHS, UL 60947-4-1, UL 60947-5-1
Features
Single Phase Sensitivity
Use With - Contactors and Starters
Mfr. Series LC1D09 to LC1D32 Contactors
Number of Poles
3
For Use With
TeSys Deca
Trip Class - Overload
10
Sensing Method
Bimetallic
Starter Type
IEC
Ambient Air Temperature For Operation
-20-60°C without derating IEC 60947-4-1
Thermal Protection Adjustment Range
5.5-8 A
Climatic Withstand
IACS E10
Relay Application
motor protection
Thermal Overload Class
class 10A IEC 60947-4-1
Tightening Torque
control circuit 1.7 N.m screw clamp terminals || power circuit 1.7 N.m screw clamp terminals
Associated Fuse Rating
4 A gG signalling circuit || 4 A BS signalling circuit
Tripping Threshold
1.14 +/- 0.06 Ir IEC 60947-4-1
Control Type
Red push-button stop || Blue push-button reset
Product Certifications
IEC || UL || CSA || CCC || EAC || BV || RINA || DNV-GL || LROS (Lloyds register of shipping) || ATEX INERIS || UKCA
Network Frequency
0 to 400 Hz
Product Name
TeSys LRD || TeSys Deca
Device Short Name
LRD
Mechanical Robustness
vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
Similar Products
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 12 A Min current, 18 A Max current, 690V AC LRD21
LRD21
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 23 A Min current, 32 A Max current, 690V AC LRD32
LRD32
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 4 A Min current, 6 A Max current, 690V AC LRD10
LRD10
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 16 A Min current, 24 A Max current, 690V AC LRD22
LRD22
Goodman
GOODMAN Overload Protector, Green Overload Protector, 2 in 60349605A
60349605A
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 2.5 A Min current, 4 A Max current, 690V AC LRD08
LRD08
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 7 A Min current, 10 A Max current, 690V AC LRD14
LRD14
Siemens
SIEMENS Overload Relay, 1NC/1NO, 50 A Min current, 200 A Max current, 690V AC 3UB81334HW2
3UB81334HW2
Can't find it?
We source what you need.