Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Motor Overload Relays → SCHNEIDER ELECTRIC Motor Controller, 1NC/4NO, 5 A Min current, 100 A Max current, 690V AC LTMR100PFM
SCHNEIDER ELECTRIC Motor Controller, 1NC/4NO, 5 A Min current, 100 A Max current, 690V AC LTMR100PFM
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LTMR100PFM

SCHNEIDER ELECTRIC Motor Controller, 1NC/4NO, 5 A Min current, 100 A Max current, 690V AC LTMR100PFM

Country of Origin China
Item Motor Controller
Auxiliary Contact Form 1NC/4NO
Minimum Overload Relay Current Setting 5:00 AM

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Motor Management System, Number of Normally Open Contacts 4, Number of Normally Closed Contacts 1, Number of Contacts Included 5, Operating Voltage 690V AC, Control Voltage 100-240V AC, Interface Profibus DP, Compatible with Series TeSys T, Overall Width 3.58 in, Standards CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508, Overall Height 2.4 in, Overall Depth 4.82 in

Technical Specifications

Country of Origin China
Item Motor Controller
Auxiliary Contact Form 1NC/4NO
Minimum Overload Relay Current Setting 5:00 AM
Maximum Overload Relay Current Setting 100 A
Maximum Voltage Rating 690V
Standards CSA C22.2 No 14, EN 60947-4-1, IACSE10, IEC 60947-4-1, KERI, nABS, nATEX, nBV, nC-tick, nCCC, nCSA, nDNV, nEAC, nGL, nLROS, nNOM, nRINA, nRMRoS, nUL, UL 508
Control Voltage 100-240V AC
Operating Voltage 690V AC
For Use With TeSys T
Interface Profibus DP
Number of Contacts Included 5
Compatible with Series TeSys T
Number of Normally Open Contacts 4
Maximum Current Rating 100 A
Minimum Current Rating 5 A
Number of Normally Closed Contacts 1
Current State 1 Guaranteed logic input 79 to 264 V >= 2 mA 25 ms
Connection Pitch 5.08 mm
Short-Circuit Withstand 100 kA conforming to EN/IEC 60947-4-1
Protection Type thermal overload protection || power factor variation || overload || locked rotor || thermal protection || reverse polarity protection || phase unbalance || earth-leakage protection || phase failure || load fluctuation || overload (long time)
Protective Treatment 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
Overvoltage Category III
Logic Input Number 6
Compatibility Code LTMR
Contacts Type And Composition 1 NO + 1 NC fault signal || 3 NO
Permissible Power 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
Fire Resistance 650°C EN/IEC 60695-2-12 || 960°C UL 94
Web Services web server
Supply Voltage Limits 93.5-264 V AC
Can't find it?
We source what you need.
Bookmarks
Recently Viewed
Compare