Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Electrical Controls
→
Motor Overload Relays
→
SCHNEIDER ELECTRIC IEC Overload Relay, 1NC/1NO, 16 A Min current, 24 A Max current, 690V AC LR3D22
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Schneider Electric
MFR#
LR3D22
SCHNEIDER ELECTRIC IEC Overload Relay, 1NC/1NO, 16 A Min current, 24 A Max current, 690V AC LR3D22
Country of Origin
Korea, Republic of
Item
IEC Overload Relay
Auxiliary Contact Form
1NC/1NO
Minimum Overload Relay Current Setting
16 A
Search Similar Products
Uncheck any specs you want to ignore
Description
IEC Overload Relay, Auxiliary Contact Form 1NO/1NC, Maximum Overload Relay Current Setting 24 A, Minimum Overload Relay Current Setting 16 A, Trip Class 10A, Maximum Voltage Rating 690V AC, NEMA Size Not Applicable, Number of Poles 3, Reset Type Auto, Manual, Mounting Style Direct To Contactor, Terminal Connection Type Screw Clamp Terminals, Compatible with Series TeSys Deca, Relay Style IEC, Overload Protection Type Thermal
Technical Specifications
Country of Origin
Korea, Republic of
Item
IEC Overload Relay
Auxiliary Contact Form
1NC/1NO
Minimum Overload Relay Current Setting
16 A
Maximum Overload Relay Current Setting
24 A
Trip Class
10A
Overload Protection Type
Thermal
Maximum Voltage Rating
690V AC
Standards
CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, EN 50495, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.4, GB/T 14048.5, REACH, RoHS, UL 60947-4-1, UL 60947-5-1
Kit Required for Retrofit Mtg.
No
Separate Mounting
No
Trip Class - Overload
10A
Frame / Series / Class / Code
Class 10
Sensing Method
Thermal
Use With - Contactors and Starters
Mfr. Series LUA1C Contactors
Number of Poles
3
Network Frequency
0 to 400 Hz
Associated Fuse Rating
4 A gG signalling circuit || 4 A BS signalling circuit
Thermal Overload Class
class 10A IEC 60947-4-1
Range
TeSys || TeSys Deca
Relay Application
motor protection
Climatic Withstand
IACS E10
Dielectric Strength
1.89 kV 50 Hz IEC 60947-1
Ambient Air Temperature For Storage
-60-70°C
Ambient Air Temperature For Operation
-20-60°C without derating IEC 60947-4-1
Device Short Name
LR3D
Product Name
TeSys LRD || TeSys Deca
Flame Retardance
V1 conforming to UL 94
Mechanical Robustness
vibrations6 Gn IEC 60068-2-6 || shocks15 Gn for 11 ms IEC 60068-2-7
Product Or Component Type
non differential thermal overload relay
Similar Products
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 12 A Min current, 18 A Max current, 690V AC LRD21
LRD21
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 23 A Min current, 32 A Max current, 690V AC LRD32
LRD32
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 4 A Min current, 6 A Max current, 690V AC LRD10
LRD10
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 16 A Min current, 24 A Max current, 690V AC LRD22
LRD22
Goodman
GOODMAN Overload Protector, Green Overload Protector, 2 in 60349605A
60349605A
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 2.5 A Min current, 4 A Max current, 690V AC LRD08
LRD08
Schneider Electric
SCHNEIDER ELECTRIC Overload Relay, 1NC/1NO, 7 A Min current, 10 A Max current, 690V AC LRD14
LRD14
Siemens
SIEMENS Overload Relay, 1NC/1NO, 50 A Min current, 200 A Max current, 690V AC 3UB81334HW2
3UB81334HW2
Can't find it?
We source what you need.