Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SQUARE D IEC Miniature Magnetic Contactor, 1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp LC1K1210U7
SQUARE D IEC Miniature Magnetic Contactor, 1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp LC1K1210U7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Square D
MFR# LC1K1210U7

SQUARE D IEC Miniature Magnetic Contactor, 1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp LC1K1210U7

Country of Origin Indonesia
Item IEC Miniature Magnetic Contactor
Auxiliary Contact Form 1NO
Coil Voltage 230-240V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The IEC Miniature Magnetic Contactor is a 3-pole, non-reversing device with 1 normally open auxiliary contact (1NO) and a 240 V AC coil. It is rated for operation with motor control and resistive loads within specified parameters and uses screw clamp terminals. Its IEC-style construction is compatible with mounting on DIN rails or plates as specified.

Series: TeSys K; Contactor Style: IEC; Action: Non-Reversing; Application: Motor Control, Resistive Load

  • Coil Voltage: 240 V AC
  • Poles / Main Contacts: 3 poles; 3 NO main contacts
  • Auxiliary Contacts: Includes 1 auxiliary contact (1NO); Auxiliary Form: 1NO
  • Electrical Connection: Screw Clamp Terminals
  • Enclosure: No Enclosure; IP Rating: IP22
  • Mounting: DIN Rail, Plate; Mounts On: Plate, Rail
  • Rated Voltage: rated for operation at voltages up to 690 V AC within the specified voltage range
  • Net Weight: 0.18 kg
  • Dimensions (Overall): 2.24 in D x 2.28 in H x 1.77 in W
  • Mechanical Durability: tested for mechanical durability up to 10 million cycles under standard conditions
  • Electrical Durability: electrical durability ratings based on standardized testing conditions; actual performance may vary depending on application specifics
  • Hold VA: 4.5 VA; Inrush VA: 30 VA
  • Embedded Surge Suppressor: No
  • Includes Auxiliary Contacts: Yes
  • Impedance: 3 mΩ
  • Fire Rating: complies with fire safety standards UL 94 V1 and relevant NF standards when tested according to their procedures
  • Impulse Withstand Voltage: rated to withstand impulse voltages up to specified levels under test conditions
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Miniature Magnetic Contactor
    Auxiliary Contact Form 1NO
    Coil Voltage 230-240V AC
    Number of Poles 3
    Full Load Amps-Inductive 12 A
    Full Load Amps-Resistive 20 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 1
    Standards BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
    Enclosure NEMA Rating No Enclosure
    HP @ 1 Phase - 230V 1-1/2
    Reversing No
    HP @ 3 Phase - 575V 10 hp
    Series TeSys K
    Impedance 3 mOhm
    Operating Speed 3600 cycles per hr
    Rated Making Capacity 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
    Signalling Circuit Frequency Less Than 400 Hz
    Application Motor Control, Resistive Load
    Rated Short-Time Withstand Current 115 A (at 50 Degrees C for 1 s Power Circuit), 105 A (at 50 Degrees C for 5 s Power Circuit), 100 A (at 50 Degrees C for 10 s Power Circuit), 75 A (at 50 Degrees C for 30 s Power Circuit), 55 A (at 50 Degrees C for 1 min Power Circuit), 50 A (at 50 Degrees C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50??C for 15 min Power Circuit)
    Fuse Amps 25 A (Power Circuit), 10 A (Signalling Circuit)
    Max. Operating Watts 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW 380 to (at 415V AC 50/60 Hz AC-3), 5.5 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 415V AC 50/60 Hz AC-3e), 5.5 kW (at 440V AC 50/60 Hz AC-3e)
    Fire Rating UL 94 V1, NF F 16-101, NF F 16-102
    Mechanical Durability 10 Mcycles
    Impulse Withstand Voltage 8 kV
    IP Rating IP22
    Rated Insulation Volts 600V, 690V
    Overvoltage Category CAT III
    Can't find it?
    We source what you need.
    Bookmarks
    Recently Viewed
    Compare