SQUARE D 3Pole3Ph24V Contactor 1NO/1NC LC1D09B7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Square D
MFR# LC1D09B7

SQUARE D 3Pole3Ph24V Contactor 1NO/1NC LC1D09B7

Country of Origin France
Standards CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508; IEC 60335-1
Pole Contact Composition 3 NO
Coil Technology Without built-in suppressor module

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600-cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Technical Specifications

Country of Origin France
Standards CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508; IEC 60335-1
Pole Contact Composition 3 NO
Coil Technology Without built-in suppressor module
Power Dissipation Per Pole 1.56 W AC-1; 0.2 W AC-3; 0.2 W AC-3e
Minimum Switching Current 5 mA for signalling circuit
Contact Compatibility M2
Mounting Support Rail; Plate
Average Impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Heat Dissipation 2 to 3 W at 50/60 Hz
Operating Time 12 to 22 ms closing; 4 to 19 ms opening
Associated Fuse Rating 10 A gG for signalling circuit conforming to IEC 60947-5-1; 25 A gG at Less than or Equal to 690 V coordination type 1 for power circuit; 20 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Non-Overlap Time 1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Auxiliary Contacts Type Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Hold-In Power Consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Control Circuit Type AC 50/60 Hz standard
Climatic Withstand IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Fire Resistance 1562°F (850°C) IEC 60695-2-1
Operating Altitude 0 to 9842.52 ft (0 to 3000 m)
Compatibility Code LC1D
Rated Short Time Withstand Current 105 A 104°F (40°C) - 10 s for power circuit; 210 A 104°F (40°C) - 1 s for power circuit; 30 A 104°F (40°C) - 10 min for power circuit; 61 A 104°F (40°C) - 1 min for power circuit; 100 A - 1 s for signalling circuit; 120 A - 500 ms for signalling circuit; 140 A - 100 ms for signalling circuit
Safety Reliability Level B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Electrical Durability 0.6 Mcycles 25 A AC-1 Less than or Equal to 440 V; 2 Mcycles 9 A AC-3 Less than or Equal to 440 V; 2 Mcycles 9 A AC-3e Less than or Equal to 440 V
Permissible Ambient Air Temperature Around The Device -40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Minimum Switching Voltage 17 V for signalling circuit
Poles Description 3P
Rated Breaking Capacity 250 A at 440 V for power circuit conforming to IEC 60947
Tightening Torque Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat 6 mm; Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat 6 mm; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2; Power circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2
Product Certifications GL; CSA; GOST; RINA; LROS (Lloyds register of shipping); UL; DNV; BV; CCC; UKCA
Mechanical Robustness Vibrations contactor open 2 Gn, 5 to 300 Hz); Vibrations contactor closed 4 Gn, 5 to 300 Hz); Shocks contactor open 10 Gn for 11 ms); Shocks contactor closed 15 Gn for 11 ms)