SQUARE D 120V 25A 3P 1NO/1NC Contactor LC1D25G7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Square D
MFR#
LC1D25G7
SQUARE D 120V 25A 3P 1NO/1NC Contactor LC1D25G7
Country of Origin
France
Standards
CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508; IEC 60335-1
Mechanical Durability
15 Mcycles
Rated Breaking Capacity
450 A at 440 V for power circuit conforming to IEC 60947
Search Similar Products
Uncheck any specs you want to ignore
Technical Specifications
Country of Origin
France
Standards
CSA C22.2 No 14; EN 60947-4-1; EN 60947-5-1; IEC 60947-4-1; IEC 60947-5-1; UL 508; IEC 60335-1
Mechanical Durability
15 Mcycles
Rated Breaking Capacity
450 A at 440 V for power circuit conforming to IEC 60947
Rated Impulse Withstand Voltage
6 kV IEC 60947
Tightening Torque
Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat 6 mm; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals flat 6 mm; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals Philips No 2; Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2; Power circuit 22.13 lbf.in (2.5 N.m) screw clamp terminals pozidriv No 2
Maximum Horse Power Rating
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors; 2 hp at 115 V AC 50/60 Hz for 1 phase motors; 7.5 hp at 230/240 V AC 50/60 Hz for 3 phase motors; 15 hp at 460/480 V AC 50/60 Hz for 3 phase motors; 20 hp at 575/600 V AC 50/60 Hz for 3 phase motors; 7.5 hp at 200/208 V AC 50/60 Hz for 3 phase motors
Climatic Withstand
IACS E10 exposure to damp heat; IEC 60947-1 Annex Q category D exposure to damp heat
Non-Overlap Time
1.5 ms on de-energisation between NC and NO contact; 1.5 ms on energisation between NC and NO contact
Rated Insulation Voltage
Power circuit 690 V IEC 60947-4-1; Power circuit 600 V CSA; Power circuit 600 V UL; Signalling circuit 690 V IEC 60947-1; Signalling circuit 600 V CSA; Signalling circuit 600 V UL
Conventional Free Air Thermal Current
10 A (at 140°F (60°C)) for signalling circuit; 40 A (at 140°F (60°C)) for power circuit
Inrush Power in VA
70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)); 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Contactor Application
Motor control; Resistive load
Minimum Switching Voltage
17 V for signalling circuit
Operating Altitude
0 to 9842.52 ft (0 to 3000 m)
Average Impedance
2 mOhm - Ith 40 A 50 Hz for power circuit
IRMS Rated Making Capacity
140 A AC for signalling circuit conforming to IEC 60947-5-1; 250 A DC for signalling circuit conforming to IEC 60947-5-1; 450 A at 440 V for power circuit conforming to IEC 60947
Auxiliary Contacts Type
Mechanically linked 1 NO + 1 NC IEC 60947-5-1; Mirror contact 1 NC IEC 60947-4-1
Poles Description
3P
Flame Retardance
V1 conforming to UL 94
Protective Treatment
THIEC 60068-2-30
Coil Technology
Without built-in suppressor module
Electrical Durability
1.65 Mcycles 25 A AC-3 Less than or Equal to 440 V; 1.4 Mcycles 40 A AC-1 Less than or Equal to 440 V; 1.65 Mcycles 25 A AC-3e Less than or Equal to 440 V
Insulation Resistance
Greater than 10 MOhm for signalling circuit
Hold-In Power Consumption in VA
7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)); 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Permissible Ambient Air Temperature Around The Device
-40 to 140°F (-40 to 60°C); 140 to 158°F (60 to 70°C) with derating
Safety Reliability Level
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1; B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product Certifications
UL; BV; RINA; GOST; DNV; LROS (Lloyds register of shipping); CCC; GL; CSA; UKCA
Heat Dissipation
2 to 3 W at 50/60 Hz
Operating Time
12 to 22 ms closing; 4 to 19 ms opening
Similar Products
Square D
SQUARE D Auxiliary Contact, 1NO/1NC, 5 A 9999D11
9999D11
Square D
SQUARE D Auxiliary Contact, 1NO/0NC, 10 A 9999SX6
9999SX6
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/2NC, 10 A LADN22
LADN22
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 1NO/1NC, 10 A LADN11
LADN11
Eaton
EATON Cutler-Hammer Auxiliary Contacts, 1NO-1NC, Size00-2 C320KGS3
C320KGS3
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/0NC, 10 A LADN20
LADN20
Square D
SQUARE D External Reset Mechanism Kit, PushButton 9066RA1
9066RA1
Square D
SQUARE D Control Kit, NEMA, Black Selector Switch 9999SC2
9999SC2
Can't find it?
We source what you need.