Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Electrical Controls
→
Electrical Contactors & Contacts
→
SIEMENS IEC Magnetic Contactor, 1NC, 220V-240V AC, 3 P, Non-Reversing, Screw 3RT20161AP62
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Siemens
MFR#
3RT20161AP62
SIEMENS IEC Magnetic Contactor, 1NC, 220V-240V AC, 3 P, Non-Reversing, Screw 3RT20161AP62
Country of Origin
Germany
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC
Coil Voltage
220/240V AC
Search Similar Products
Uncheck any specs you want to ignore
Description
The Siemens IEC Magnetic Contactor is a 3-pole, non-reversing, coil-operated switch rated for operation within the specified voltage range of 220–240 V AC. It includes auxiliary contacts configured as 1 NC and has three normally open main contacts; connections are made via screw terminals. The unit belongs to the SIRIUS 3RT20 series (frame S00) and supports DIN Rail or surface mounting; it has an IP20 rating indicating limited ingress protection.
Key features
Technical Specifications
Country of Origin
Germany
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC
Coil Voltage
220/240V AC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
22 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw
Number of Auxillary Contacts
1
Standards
REACH Art 33, WEEE (2012/19/EU)
Enclosure NEMA Rating
No Enclosure
HP @ 1 Phase - 230V
1
Reversing
No
Frame / Series / Class / Code
S00
HP @ 3 Phase - 575V
7 1/2 hp
Series
SIRIUS 3RT20
Watts Loss
0.3W (Current Dependent); 4.4W (Current Independent)
Max. Operating Watts
4 kW (at 400V, AC-3), 13 kW (at 400V, AC-1)
IP Rating
IP20
Mechanical Operating Durability
30,000,000
NEMA Enclosure Rating
No Enclosure
Maximum Voltage Rating
690V AC
Response Time
10 to 18 msec (AC Operation Closing Delay Operation Opening Delay Operating Times for 1.0 x Us1), 15 to 17.5 msec (DC Operation Opening Delay Operating Times For 0.8 ... 1.1 X Us1), 16 to 17.5 msec (DC Operation Opening Delay Operating Times for 1.0 x Us), 4 to 16 msec (AC Operation Opening Delay Operating Times for 0.8 ... 1.1 X Us1), 4 to 16 msec (AC Operation Opening Delay Operating Times for 1.0 x Us), 50 to 170 msec (DC Operation Closing Delay Operating Times for 0.8 ... 1.1 X Us1), 55 to 80 msec (DC Operation Closing Delay Operating Times for 1.0 x Us), 9 to 38 msec (AC Operation Closing Delay)
Horsepower @ Three Phase - 600V AC
7 1/2 hp
Mounting Postion
Vertical
Number of Normally Open Main Contacts
3
Minimum Operating Temperature
-13 Degrees F
Full Load Current - Inductive
9 A
Embedded Surge Suppressor
No
Similar Products
Square D
SQUARE D Auxiliary Contact, 1NO/1NC, 5 A 9999D11
9999D11
Square D
SQUARE D Auxiliary Contact, 1NO/0NC, 10 A 9999SX6
9999SX6
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/2NC, 10 A LADN22
LADN22
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 1NO/1NC, 10 A LADN11
LADN11
Eaton
EATON Cutler-Hammer Auxiliary Contacts, 1NO-1NC, Size00-2 C320KGS3
C320KGS3
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/0NC, 10 A LADN20
LADN20
Square D
SQUARE D External Reset Mechanism Kit, PushButton 9066RA1
9066RA1
Square D
SQUARE D Control Kit, NEMA, Black Selector Switch 9999SC2
9999SC2
Can't find it?
We source what you need.