Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SCHNEIDER ELECTRIC IEC Miniature Magnetic Contactor, 1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp LC1K0910U7
SCHNEIDER ELECTRIC IEC Miniature Magnetic Contactor, 1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp LC1K0910U7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LC1K0910U7

SCHNEIDER ELECTRIC IEC Miniature Magnetic Contactor, 1NO, 240V AC, 3 P, Non-Reversing, Screw Clamp LC1K0910U7

Country of Origin Indonesia
Item IEC Miniature Magnetic Contactor
Auxiliary Contact Form 1NO
Coil Voltage 230-240V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The SCHNEIDER ELECTRIC IEC Miniature Magnetic Contactor is a 3-pole, non-reversing device with a 240 V AC coil (coil voltage). It is part of the TeSys K family and is rated for operation with motor control and resistive loads within specified parameters. It uses screw clamp terminals and has no enclosure or embedded surge suppressor. The contactor features 3 normally open main contacts and 1 auxiliary contact, rated according to specifications.

Key features

  • Coil voltage: 240 V AC; Hold VA: 4.5 VA; Inrush VA: 30 VA; Watts loss: 1.3 W; Operating times: 10 to 20 ms (energise NO close, de-energise NO open)
  • Poles/contacts: 3 poles; 3 normally open main contacts; Auxiliary contacts: 1 NO (1 auxiliary contact)
  • Reversing: Non-Reversing; Frame/series: TeSys K / TeSys; Contactor style: IEC
  • Electrical ratings: Max voltage 690 V AC; Frequency 50/60 Hz; Overvoltage CAT III
  • Current ratings: Full Load Amps – Inductive 9 A; Full Load Amps – Resistive 20 A; Rated Making Capacity 110 A; Rated Breaking Capacity up to 110 A at multiple voltages
  • Standards: CSA, UKCA, UL Listed; Enclosure: No Enclosure
  • Terminal: Screw Clamp; Embedded surge suppressor: No; Insulation resistance: Greater Than 10 MΩ (Signalling Circuit)
  • Dimensional footprint: Depth 1.97 in; Height 1.73 in; Width 1.73 in
  • Additional electrical characteristics: Inrush 30 VA; Hold 4.5 VA; Impedance 3 mΩ; Shock resistance up to 10–15 G depending on axis/state; Vibration resistance 4 G (Closed), 2 G (Open)
  • Environment and safety marks: Mercury Free, Toxic Heavy Metal Free; Fire rating: UL 94 V1, NF F 16-101, NF F 16-102
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Miniature Magnetic Contactor
    Auxiliary Contact Form 1NO
    Coil Voltage 230-240V AC
    Number of Poles 3
    Full Load Amps-Inductive 9 A
    Full Load Amps-Resistive 20 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 1
    Standards CSA, UKCA, UL Listed
    HP @ 3 Phase - 575V 5 hp
    Enclosure NEMA Rating No Enclosure
    HP @ 1 Phase - 230V 1-1/2
    Reversing No
    Frame / Series / Class / Code TeSys
    Series TeSys K
    Max. Operating Watts 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW 380 to (at 415V AC 50/60 Hz AC-3), 4 kW (at 440V AC 50/60 Hz AC-3), 4 kW (at 480V AC 50/60 Hz AC-3), 4 kW (at 500 to 600V AC 50/60 Hz AC-3), 4 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 415V AC 50/60 Hz AC-3e), 4 kW (at 440V AC 50/60 Hz AC-3e), 4 kW (at 480V AC 50/60 Hz AC-3e), 4 kW (at 500 to 600V AC 50/60 Hz AC-3e), 4 kW (at 660 to 690V AC 50/60 Hz AC-3e)
    Overvoltage Category CAT III
    Application Motor Control, Resistive Load
    Rated Making Capacity 110 A
    Hold VA 4.5 VA
    Operating Time 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
    Operating Speed 3600 cycles per hr
    Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
    Fuse Amps 25 A (Power Circuit), 10 A (Signalling Circuit)
    Fire Rating UL 94 V1, NF F 16-101, NF F 16-102
    Rated Breaking Capacity 110 A @ 415V, 440V, 220 to 230V, 380 to 400 V; 80 A @ 500V; 70 A @ 660 to 690V
    Environmental Attributes Mercury Free, Toxic Heavy Metal Free
    Shock Resistance 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)