Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Electrical Controls
→
Electrical Contactors & Contacts
→
SCHNEIDER ELECTRIC IEC Miniature Magnetic Contactor, 1NO, 110V AC, 3 P, Non-Reversing, Screw Clamp LC1K0610F7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Schneider Electric
MFR#
LC1K0610F7
SCHNEIDER ELECTRIC IEC Miniature Magnetic Contactor, 1NO, 110V AC, 3 P, Non-Reversing, Screw Clamp LC1K0610F7
Country of Origin
Indonesia
Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
110V AC
Search Similar Products
Uncheck any specs you want to ignore
Description
The Schneider Electric IEC Miniature Magnetic Contactor is a 3-pole, non-reversing, electrically operated switching device (TeSys series) with a 110 V AC coil. It has three normally open main contacts and one normally open auxiliary contact, and uses screw clamp terminals for wiring. Suitable for motor control applications within specified parameters, it mounts on DIN rails or plates and ships without an enclosure; the user should provide an appropriate enclosure as needed.
Action: Non-Reversing
Technical Specifications
Country of Origin
Indonesia
Item
IEC Miniature Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
110V AC
Number of Poles
3
Full Load Amps-Inductive
6 A
Full Load Amps-Resistive
15 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Enclosure NEMA Rating
No Enclosure
Reversing
No
Frame / Series / Class / Code
TeSys
HP @ 1 Phase - 230V
1-1/2
HP @ 3 Phase - 575V
3 hp
Series
TeSys K
Application
Motor Control
Net Weight
0.18 kg
Shock Resistance
10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Operating Speed
3600 cycles per hr
Hold VA
4.5 VA
Electrical Durability
1.3 Mcycles (6 A, AC-3, Less than 440 V); 1.3 Mcycles (6 A, AC-3e, Less than 440 V)
Operating Time
10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
Switching Voltage
17 V (Signalling Circuit)
Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 20 A (at 50°C for 15 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit)
Watts Loss
1.3W
Insulation Resistance Range
Greater Than 10 MOhms (Signalling Circuit)
Rated Insulation Volts
600V, 690V
Vibration Resistance
4 G (Contactor Closed), 2 G (Contactor Open)
Similar Products
Square D
SQUARE D Auxiliary Contact, 1NO/1NC, 5 A 9999D11
9999D11
Square D
SQUARE D Auxiliary Contact, 1NO/0NC, 10 A 9999SX6
9999SX6
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/2NC, 10 A LADN22
LADN22
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 1NO/1NC, 10 A LADN11
LADN11
Eaton
EATON Cutler-Hammer Auxiliary Contacts, 1NO-1NC, Size00-2 C320KGS3
C320KGS3
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/0NC, 10 A LADN20
LADN20
Square D
SQUARE D External Reset Mechanism Kit, PushButton 9066RA1
9066RA1
Square D
SQUARE D Control Kit, NEMA, Black Selector Switch 9999SC2
9999SC2
Can't find it?
We source what you need.