Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Electrical Controls
→
Electrical Contactors & Contacts
→
SCHNEIDER ELECTRIC IEC Magnetic Contactor, No Auxiliary Contacts, 24V AC, 3 P, Reversing, Screw Clamp LC2K0910B7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Schneider Electric
MFR#
LC2K0910B7
SCHNEIDER ELECTRIC IEC Magnetic Contactor, No Auxiliary Contacts, 24V AC, 3 P, Reversing, Screw Clamp LC2K0910B7
Country of Origin
Korea, Republic of
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
24V AC
Search Similar Products
Uncheck any specs you want to ignore
Description
The Schneider Electric IEC Magnetic Contactor is a reversing, 3-pole switching device rated for operation within the specified IEC standards. It features a 24 V AC coil, screw clamp terminals, and no auxiliary contacts, and is part of the TeSys K family. Its applications include motor control and resistive load switching, and it is rated for use at voltages up to 690 V AC.
Key features
Technical Specifications
Country of Origin
Korea, Republic of
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NO
Coil Voltage
24V AC
Number of Poles
3
Full Load Amps-Inductive
9 A
Full Load Amps-Resistive
20 A
Reversing Capability
Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
1
Standards
BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Enclosure NEMA Rating
No Enclosure
Reversing
Yes
Series
TeSys K
Frame / Series / Class / Code
TeSys
Fuse Amps
25 A (Power Circuit), 10 A (Signalling Circuit)
Max. Operating Watts
2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
Fire Rating
UL 94 V1, NF F 16-101, NF F 16-102
Switching Voltage
17 V (Signalling Circuit)
Electrical Durability
0.18 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (9 A, AC-3, Less than 440 V); 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
Operating Speed
3600 cycles per hr
Operating Time
10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Features
Preassembled with Reversing Power Busbar
Switching Current
5 mA (Signalling Circuit)
Hold VA
4.5 VA
Inrush VA
30 VA
Rated Short-Time Withstand Current
90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
Impedance
3 mOhm
Control Circuit Voltage Limits
Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Overvoltage Category
CAT III
Similar Products
Square D
SQUARE D Auxiliary Contact, 1NO/1NC, 5 A 9999D11
9999D11
Square D
SQUARE D Auxiliary Contact, 1NO/0NC, 10 A 9999SX6
9999SX6
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/2NC, 10 A LADN22
LADN22
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 1NO/1NC, 10 A LADN11
LADN11
Eaton
EATON Cutler-Hammer Auxiliary Contacts, 1NO-1NC, Size00-2 C320KGS3
C320KGS3
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/0NC, 10 A LADN20
LADN20
Square D
SQUARE D External Reset Mechanism Kit, PushButton 9066RA1
9066RA1
Square D
SQUARE D Control Kit, NEMA, Black Selector Switch 9999SC2
9999SC2
Can't find it?
We source what you need.