Brand Schneider Electric
MFR# LC1K1210F7

SCHNEIDER ELECTRIC IEC Magnetic Contactor, No Auxiliary Contacts, 110V AC, 3 P, Non-Reversing, Screw Clamp LC1K1210F7

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NO
Coil Voltage 110V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, non-reversing, electrically operated switch rated for operation within the specified parameters. It uses a 110 V AC coil and is part of the TeSys K family. The device features screw clamp terminals and supports mounting on DIN rails or plates. It has three main normally open contacts and is intended for use with compatible load types as specified. The contactor is rated for operation up to 690 V AC; enclosure options are available separately.

Coil voltage: 110 V AC

  • Poles / main contacts: 3P, 3 NO
  • Reversing: Non-Reversing
  • Terminals / mounting: Screw Clamp Terminals; Mounting: DIN Rail, Plate
  • Max voltage: 690 V AC
  • Full load amps: 20 A resistive, 12 A inductive
  • Frequency: 50/60 Hz
  • Series: TeSys K
  • Enclosure / IP rating: No Enclosure; IP22
  • Impulse withstand: 8 kV
  • Inrush / Hold VA: 30 VA (inrush), 4.5 VA (holding)
  • Dimensions / weight: 1.77 in wide; 2.28 in high; 2.24 in deep; 0.18 kg
  • Operating cycles: 3600 cyc/h
  • Certifications: CB Scheme; CCC; UL; CSA; EAC; CE; UKCA
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NO
    Coil Voltage 110V AC
    Number of Poles 3
    Full Load Amps-Inductive 12 A
    Full Load Amps-Resistive 20 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 1
    Standards BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
    Enclosure NEMA Rating No Enclosure
    Frame / Series / Class / Code TeSys
    Series TeSys K
    Reversing No
    Rated Making Capacity 110 A (AC Signalling Circuit), 144 A (AC Power Circuit)
    Fire Rating UL 94 V1, NF F 16-101, NF F 16-102
    Electrical Durability 0.3 Mcycles (20 A, AC-1, Less than 440 V); 1.3 Mcycles (12 A, AC-3, Less than 440 V); 1.3 Mcycles (12 A, AC-3e, Less than 440 V)
    Impulse Withstand Voltage 8 kV
    Switching Current 5 mA (Signalling Circuit)
    Impedance 3 mOhm
    Mechanical Durability 10 Mcycles
    Inrush VA 30 VA
    Operating Time 10 to 20 ms (Coil De-Energisation and NO Opening), 10 to 20 ms (Coil Energisation and NO Closing)
    Control Circuit Voltage Limits Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
    Application Motor Control, Resistive Load
    Rated Insulation Volts 600V, 690V
    Shock Resistance 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
    Signalling Circuit Frequency Less Than 400 Hz
    Overvoltage Category CAT III