Brand Schneider Electric
MFR# DPE09BL

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp DPE09BL

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NO
Coil Voltage 24V DC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Schneider Electric IEC Magnetic Contactor, 3-pole, 24 V DC coil, non-reversing, 1 normally open auxiliary contact, mounted with screw clamp terminals. This IEC-style magnetic contactor is rated for operation within the specified voltage and current ranges in motor control and resistive load applications. It features a TeSys Easy frame and is suitable for installation in control panels with standard dimensions; complies with relevant standards.

Poles: 3; Main Contacts: 3 NO; Auxiliary Contacts: 1 NO; Coil Voltage: 24 V DC; Reversing: Non-Reversing

  • Frame: TeSys Easy; Control: 50/60 Hz; Electrical Connection: Screw Clamp Terminals
  • Mounting: DIN Rail, Plate; Mounts On: Plate, Rail; Enclosure: IP20; NEMA Rating: 3R; 4
  • Maximum Voltage: rated for operation up to 690 V AC / 300 V DC within specified conditions
  • Rated Voltage: rated for use at voltages up to these levels under specified conditions
  • Rated Making Capacity: 250 A @ 440 V (Power Circuit); 140 A (AC Signalling); 250 A (DC Signalling) → rated making capacity at specified voltages within the product's electrical ratings
  • Max. Operating Watts: 2.2 kW at 220–230 V AC; 4 kW at 380–400 V AC; 4 kW at 415–440 V AC; 5.5 kW at 500–690 V AC → capable of operating within the specified wattage ranges when used according to manufacturer instructions
  • Full Load Amps: Inductive 9 A; Resistive 9 A → rated for continuous operation at these current levels under normal conditions
  • Frequency: 50/60 Hz; Impedance: 2.5 mOhm
  • Impulse Withstand Voltage: 6 kV → withstands impulse voltages up to this level as per testing standards; does not imply safety guarantee during actual use; Includes Auxiliary Contacts: Yes; Non-Overlap Time: 1.5 ms
  • Operating Times (Closing/Opening): 65.45–88.55 ms / 20–30 ms → typical switching times based on design specifications; actual performance may vary depending on application conditions
  • Shock Resistance: 15 G (Closed); 10 G (Open); Vibration Resistance: 4 G (Closed); 2 G (Open) → tested resistance levels; does not imply immunity from damage or failure outside tested parameters
  • Thermal/Temperature: Max Operating Temperature 140 °F; Max Temperature 850 °C → rated for operation within these temperature ranges as per specifications; does not guarantee performance outside these limits
  • Rated Insulation Volts: 600/690 V; Special Features: Overvoltage Category III; Min Switching Voltage 17 V (Signalling Circuit); Insulation Resistance 10 MΩ (Signalling Circuit) → conforms to insulation ratings and categories defined by standards but does not guarantee protection against all electrical faults or failures
  • Electrical Durability: 1,000,000 cycles (overall); 0.6 Mcycles (20 A, AC-1, <440 V); 1 Mcycles (9 A, AC-3, <440 V)
  • Environments/Standards: Mercury Free; Toxic Heavy Metal Free; Pollution Degree 3; Standards: CSA, EN 60947-4-1, EN 60947-5-1, UL Listed, IEC 60947-4-1, IEC 60947-5-1, CSA C22.2 No 14
  • Weight: 0.32 kg; Depth: 3.39 in; Height: 3.03 in; Width: 1.77 in
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NO
    Coil Voltage 24V DC
    Number of Poles 3
    Full Load Amps-Inductive 9 A
    Full Load Amps-Resistive 9 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 1
    Standards CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
    Enclosure NEMA Rating 3R; 4
    HP @ 3 Phase - 575V 7 1/2 hp
    Frame / Series / Class / Code TeSys
    Reversing No
    Special Features Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
    Features Without Built-In Suppressor Module
    Application Motor Control, Resistive Load
    Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
    Control Circuit Voltage Limits Drop-Out: 0.1 to 0.3 Uc (at 70°C); Operational: 0.8 to 1.25 Uc (at 60°C), 1 to 1.25 Uc (at 70°C)
    Environmental Attributes Mercury Free, Toxic Heavy Metal Free, Pollution Degree 3
    Rated Breaking Capacity 250 A @ 440V
    Electrical Durability 0.6 Mcycles (20 A, AC-1, Less than 440 V); 1 Mcycles (9 A, AC-3, Less than 440 V)
    Series TeSys Easy
    Rated Insulation Volts 600V, 690V
    Fuse Amps 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
    Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
    Operating Time 65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening)
    Non-Overlap Time 1.5 ms
    Switching Current 5 mA (Signalling Circuit)