Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NO, 24V AC, 3 P, Non-Reversing, Screw Clamp DPE09B7
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NO, 24V AC, 3 P, Non-Reversing, Screw Clamp DPE09B7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# DPE09B7

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NO, 24V AC, 3 P, Non-Reversing, Screw Clamp DPE09B7

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NO
Coil Voltage 24V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V AC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 9 A, Reversing Capability Non-Reversing, Overall Height 3.03 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Easy, Number of Auxillary Contacts 1, Contactor Style IEC, Horsepower @ Three Phase - 240V AC 2 hp

Technical Specifications

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NO
Coil Voltage 24V AC
Number of Poles 3
Full Load Amps-Inductive 9 A
Full Load Amps-Resistive 9 A
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Number of Auxillary Contacts 1
Standards CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
HP @ 3 Phase - 575V 7 1/2 hp
Reversing No
Frame / Series / Class / Code TeSys
Enclosure NEMA Rating 3R; 4
Special Features Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
Application Motor Control, Resistive Load
Features Without Built-In Suppressor Module
Operating Speed 3600 cycles per hr
IP Rating IP20
Overvoltage Category CAT III
Tightening Torque 1.7 Nm
Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
Impulse Withstand Voltage 6 kV
Signalling Circuit Frequency 25 to 400 Hz
Inrush VA 70 VA
Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Impedance 2.5 mOhm
Control Circuit Voltage Limits Drop-Out: 0.3 to 0.6 Uc (at 70°C 50/60 Hz); Operational: 0.8 to 1.1 Uc (at 60°C 50 Hz 0.85 to 1.1 Uc (at 60°C 60 Hz), 1 to 1.1 Uc (at 70°C 50/60 Hz)
Can't find it?
We source what you need.
Bookmarks
Recently Viewed
Compare