Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NO, 120V AC, 3 P, Non-Reversing, Screw Clamp DPE18G7
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NO, 120V AC, 3 P, Non-Reversing, Screw Clamp DPE18G7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# DPE18G7

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NO, 120V AC, 3 P, Non-Reversing, Screw Clamp DPE18G7

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NO
Coil Voltage 120V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, non-reversing switching device with a 120 V AC coil and 1 normally open auxiliary contact (1NO). It uses screw clamp terminals and is rated for use with motor control and resistive loads within specified parameters. The device is part of the TeSys family and is rated for operation at 50/60 Hz within the specified voltage range up to 690 V AC. Main contacts total 3 NO, complemented by 1 NO auxiliary contact; does not include reversing functionality.

Coil voltage: 120 V AC

  • Poles/Main Contacts: 3 poles; 3 NO main contacts; Auxiliary contact: 1 NO
  • Reversing: Non-Reversing
  • Terminals: Screw Clamp
  • Enclosure: IP20; Enclosure ratings are as specified; no additional enclosure features implied
  • Series: TeSys
  • Frequency: 50/60 Hz
  • Maximum/Insulation Voltage: 690 V AC; Rated Insulation: 600/690 V
  • Full Load Amps: Inductive 18 A; Resistive 18 A
  • Rated Making Capacity: Rated making capacity based on standard testing conditions
  • Rated Breaking Capacity: Rated breaking capacity under specified test conditions
  • Embedded Surge Suppressor: does not include an embedded surge suppressor
  • Dimensions/Weight: Depth 3.39 in; Height 3.03 in; Width 1.77 in; Net weight 0.325 kg
  • Mounting: compatible with mounting on DIN rail or plate according to installation instructions
  • Mechanical/Electrical Durability: tested durability within standardized cycles under controlled conditions
  • Operating Time/Non-Overlap: operating times are based on typical performance specifications under test conditions
  • Hold VA: power consumption during holding is within the rated values at specified frequencies and temperatures
  • Impulse/Signal: signal characteristics are as per manufacturer specifications for signalling circuits only
  • Fuses: fuse ratings are provided as per product design specifications, subject to proper application guidelines
  • Standards: CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
  • Special Features: Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MΩ Signalling Circuit
  • Environmental: Mercury Free; Toxic Heavy Metal Free; Pollution Degree 3
  • Series/Model Details: TeSys
  • Additional ratings: Max. Temperature 850°C (max.), Maximum Operating Temperature 140°F; Rated Voltage 690V AC, 300V DC; Resistance/Impedance 2.5 mΩ
  • Reversing/Signalling: Non-Reversing; Includes Auxiliary Contacts: Yes
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NO
    Coil Voltage 120V AC
    Number of Poles 3
    Full Load Amps-Inductive 18 A
    Full Load Amps-Resistive 18 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 1
    Standards CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL Listed, UL 60947-4-1
    Frame / Series / Class / Code TeSys
    Reversing No
    HP @ 3 Phase - 575V 10 hp
    Enclosure NEMA Rating 3R; 4
    Special Features Overvoltage Category III; Minimum Switching Voltage 17 V Signalling Circuit; Insulation Resistance 10 MOhm Signalling Circuit
    Features Without Built-In Suppressor Module
    Application Motor Control, Resistive Load
    Switching Current 5 mA (Signalling Circuit)
    Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
    Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
    Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
    Series TeSys Easy
    Fuse Amps 10 A (Signalling Circuit), 40 A (Type 1 Power Circuit), 25 A (Type 2 Power Circuit)
    Electrical Durability 1 Mcycles (18 A, AC-3, Less than 440 V); 0.6 Mcycles (25 A, AC-1, Less than 440 V)
    Impulse Withstand Voltage 6 kV
    Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
    Max. Operating Watts 4 kW (at 220 to 230V AC 50/60 Hz), 7.5 kW (at 380 to 400V AC 50/60 Hz), 9 kW (at 415V AC 50/60 Hz), 9 kW (at 440V AC 50/60 Hz), 10 kW (at 500V AC 50/60 Hz), 10 kW (at 660 to 690V AC 50/60 Hz)
    Net Weight 0.325 kg
    Watts Loss 2 to 3W