Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp LC1D40ABD
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp LC1D40ABD
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LC1D40ABD

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp LC1D40ABD

Country of Origin Korea, Republic of
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24V DC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, non-reversing electrical switching device rated for operation with motor control and resistive loads within specified parameters. It features a 24 V DC coil, 1NO/1NC auxiliary contacts, and screw clamp terminals. The unit belongs to the TeSys Deca family and carries an IEC design. It has an IP20, No Enclosure rating, contains an integrated surge suppression component (note: does not guarantee protection), a protective cover, and Everlink power connections for wiring. Rated for operation within the specified electrical ratings and conditions.

Key features

  • Poles/Main contacts: 3 poles; 3 normally open main contacts; 2 auxiliary contacts (1NO/1NC)
  • Coil and control: Coil voltage 24 V DC; configured as non-reversing (no implication of performance guarantee)
  • Frame/series and standards: Series TeSys Deca; Contactor style IEC; conforms to these standards; compliance does not imply specific performance outcomes
  • Electrical ratings: Phase Three; Frequency 50/60 Hz; Rated for operation within the specified electrical ratings and conditions; Overvoltage CAT III
  • Enclosure and protection: IP20; No Enclosure; equipped with a surge suppression feature (does not guarantee protection against all surges); Protective cover included
  • Connections: designed for electrical connections using specified terminals and connections; no guarantee of compatibility beyond specifications
  • Physical size and weight: Width 2.17 in; Depth 4.72 in; Height 4.80 in; Net weight 0.925 kg
  • Durability and duty: tested to cycle counts under standard test conditions (performance may vary in actual use)
  • Electrical ratings (current): rated current capacities based on standard testing conditions within specified load types; Full Load Amps - Inductive 40 A; Full Load Amps - Resistive 60 A; Rated Making Capacity up to 800 A @ 440 V (Power Circuit)
  • Operating performance: typical switching times observed during testing under nominal conditions (not guaranteed in all applications)
  • Other ratings: Rated Short-Time Withstand Current includes values such as 320 A (40°C, 10 s) and 720 A (40°C, 1 s) for Power Circuit; Signalling Circuit values also listed
  • Environmental and materials: Mercury Free, PVC Free, Pollution Degree 3; Fire Resistant and Insulation Resistant
  • Reversing: No (Non-Reversing)
  • Technical Specifications

    Country of Origin Korea, Republic of
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 24V DC
    Number of Poles 3
    Full Load Amps-Inductive 40 A
    Full Load Amps-Resistive 60 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
    HP @ 1 Phase - 230V 5
    Enclosure NEMA Rating No Enclosure
    Reversing No
    Frame / Series / Class / Code TeSys
    HP @ 3 Phase - 575V 30 hp
    Series TeSys Deca
    Includes Everlink Power Connections
    Environmental Attributes Mercury Free, PVC Free, Pollution Degree 3
    Rated Short-Time Withstand Current 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
    Features Built-In Bi-Directional Peak Limiting Diode Suppressor
    Control Circuit Voltage Limits Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C); Operational DC: 0.75 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
    Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
    Tightening Torque 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit)
    IP Rating IP20
    Max. Operating Watts 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 11 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 415 to 440V AC 50/60 Hz AC-3), 22 kW (at 500V AC 50/60 Hz AC-3), 30 kW (at 660 to 690V AC 50/60 Hz AC-3), 9 kW (at 400V AC 50/60 Hz AC-4), 18.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 11 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 415 to 440V AC 50/60 Hz AC-3e), 22 kW (at 500V AC 50/60 Hz AC-3e), 30 kW (at 660 to 690V AC 50/60 Hz AC-3e)
    Switching Current 5 mA (Signalling Circuit)
    Switching Voltage 17 V (Signalling Circuit)
    Non-Overlap Time 1.5 ms
    Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 800 A @ 440V (Power Circuit)