Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp LC1D12BL
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp LC1D12BL
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LC1D12BL

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V DC, 3 P, Non-Reversing, Screw Clamp LC1D12BL

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24V DC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The item is an IEC Magnetic Contactor from Schneider Electric (TeSys series). It is a 3-pole, non-reversing device with a 24 V DC coil. Equipped with 1 normally open and 1 normally closed auxiliary contact for control circuit connections. Features screw clamp terminals; suitable for installation in appropriate enclosures according to applicable standards. Rated for use in motor control and resistive load applications within specified electrical parameters.

Coil Voltage: 24 V DC

  • Poles / Main Contacts: 3 poles; 3 normally open main contacts
  • Auxiliary Contacts: 2 total (1NO/1NC)
  • Reversing: Non-Reversing
  • Electrical Connection: Screw Clamp Terminals
  • Frame / Series: TeSys Deca
  • Enclosure / Rating: IP20; Does not include an enclosure; installation should be performed in accordance with relevant safety standards
  • Maximum Voltage: 690 V AC, 300 V DC
  • Rated Making Capacity: 250 A @ 440 V (Power Circuit); 140 A (AC Signalling); 250 A (DC Signalling)
  • Mechanical Durability: 30 Mcycles
  • Weight: 0.485 kg
  • Dimensions: Width 1.77 in, Height 3.03 in, Depth 3.74 in
  • Standards: EN 60947-4-1, EN 60947-5-1, UL 508, Complies with applicable recognized safety standards as indicated by listing certifications
  • Fire Rating: Meets the UL 94 V1 flammability rating standard (note: does not imply fire resistance or safety guarantee)
  • Series: TeSys Deca
  • Frequency: 50/60 Hz
  • Phase: Three
  • Includes: Protective Cover, Auxiliary Contacts
  • Embedded Surge Suppressor: Includes a surge suppression component rated within specified limits; proper application required to ensure performance
  • Environmental Attributes: Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
  • Maximum Operating Temperature: 140°F
  • Max. Temperature: 850°C
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 24V DC
    Number of Poles 3
    Full Load Amps-Inductive 12 A
    Full Load Amps-Resistive 25 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
    Reversing No
    Frame / Series / Class / Code TeSys
    Enclosure NEMA Rating No Enclosure
    HP @ 3 Phase - 575V 10 hp
    Series TeSys Deca
    Mechanical Durability 30 Mcycles
    Tightening Torque 1.7 Nm
    Control Circuit Voltage Limits Drop-Out DC: 0.1 to 0.3 Uc (at -40 to 70°C), Operational DC: 0.8 to 1.25 Uc (at -40 to 60°C), 1 to 1.25 Uc (at 60 to 70°C)
    Switching Voltage 17 V (Signalling Circuit)
    Operating Time 65.45 to 88.55 ms (Closing), 20 to 30 ms (Opening)
    Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
    Electrical Durability 2 Mcycles (12 A, AC-3, Less than 440 V); 0.8 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (12 A, AC-3e, Less than 440 V)
    Max. Operating Watts 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3), 7.5 kW (at 500V AC 50/60 Hz AC-3), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 3.7 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3e), 7.5 kW (at 500V AC 50/60 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
    Switching Current 5 mA (Signalling Circuit)
    Shock Resistance 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
    Non-Overlap Time 1.5 ms
    Rated Insulation Volts 600V, 690V
    Rated Short-Time Withstand Current 105 A (at 40 Degrees C for 10 s Power Circuit), 210 A (at 40 Degrees C for 1 s Power Circuit), 30 A (at 40 Degrees C for 10 min Power Circuit), 61 A (at 40 Degrees C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
    Net Weight 0.485 kg