SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V AC, 3 P, Non-Reversing, Screw Clamp LC1D09B7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LC1D09B7

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V AC, 3 P, Non-Reversing, Screw Clamp LC1D09B7

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

TeSys Deca contactor, 3 poles (3NO), for motor control applications up to 9A/690V AC-3/3e (4kW@400V). They can be used to create motor starters for almost any type of application. It provides a 24V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by screw clamp terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability to demanding applications. Compact (45mm width), DIN-rail mounting or screw fixing. Contactor is rated for 20HP at 200-208VAC, 25HP at 240VAC, 60HP at 480VAC and 60HP at 600VAC three phase. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine). When used with a 480VAC up to 35A circuit breaker, this contactor can have a SCCR up to 85kA. When used with up to a 600VAC 25A Class J or CC fuse, this contactor can have a SCCR up to 100kA. Contactor is supplied with a 24 VAC 50/60 Hz coil. Contactor has one normally open and one normally closed auxiliary contact built-in as standard. The NC contact is mirror certified. Screw clamp terminals are used for load and auxiliary connections. An extensive line of accessories makes it easy to meet the requirements of most applications. The contactor is 3.15 inches tall, 1.77 inches wide and 3.39 inches deep. It weighs 0.71 lbs. Contactor is certified to UL, CSA, IEC, CCC, EAC and Marine standards.

Technical Specifications

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24V AC
Number of Poles 3
Full Load Amps-Inductive 9 A
Full Load Amps-Resistive 20 A
Reversing Capability Non-Reversing
Terminal Connection Type Screw Clamp
Number of Auxillary Contacts 2
Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
Frame / Series / Class / Code TeSys
HP @ 3 Phase - 575V 7 1/2 hp
Reversing No
Enclosure NEMA Rating No Enclosure
HP @ 1 Phase - 230V 1
Series TeSys Deca
Includes Protective Cover Yes
Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Max. Operating Watts 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Tightening Torque 1.7 Nm
Fire Rating UL 94 V1
Rated Breaking Capacity 250 A @ 440V
Impulse Withstand Voltage 6 kV
Rated Short-Time Withstand Current 105 A (at 40 Degrees C for 10 s Power Circuit), 210 A (at 40 Degrees C for 1 s Power Circuit), 30 A (at 40 Degrees C for 10 min Power Circuit), 61 A (at 40 Degrees C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability 0.6 Mcycles (25 A, AC-1, Less than 440 V); 2 Mcycles (9 A, AC-3, Less than 440 V); 2 Mcycles (9 A, AC-3e, Less than 440 V)
Overvoltage Category CAT III
Non-Overlap Time 1.5 ms
Application Motor Control, Resistive Load
Impedance 2.5 mOhm