SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V-60V AC/DC, 3 P, Non-Reversing, Screw Clamp LC1D25BNE
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LC1D25BNE

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V-60V AC/DC, 3 P, Non-Reversing, Screw Clamp LC1D25BNE

Country of Origin Korea, Republic of
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24-60V AC/DC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

This Schneider Electric IEC Magnetic Contactor (TeSys Deca) is a 3-pole, non-reversing device rated for switching within specified electrical parameters. It is designed for operation with coil voltages between 24 and 60 V (AC/DC). It contains auxiliary contacts rated for specified electrical loads. It features an IP20 enclosure with a protective cover and is suitable for use within the specified voltage ratings and load types as per manufacturer specifications. Compatible with mounting methods such as DIN rail or plate, according to installation guidelines.

Coil voltage: Rated coil voltage: 24–60 V AC/DC

  • Auxiliary contacts: Included; ratings should be verified for specific applications
  • Main/auxiliary configuration: Configured as a non-reversing device with three poles
  • Terminals: Screw clamp terminals suitable within specified wire ranges
  • Series/standards: Conforms to applicable standards listed but does not imply certification beyond those standards
  • Enclosure and mounting: IP20 enclosure rating; compatible with mounting methods such as DIN rail or plate, according to installation guidelines
  • Maximum voltage and current: Rated for maximum voltage up to approximately 690 V AC; Full Load Amps: 25 A (Inductive), 40 A (Resistive) under standard conditions
  • Making capacity: Capacities are based on tested conditions but do not guarantee performance under all circumstances
  • Mechanical/Electrical durability: Durability figures are based on testing cycles under specific test conditions, not indicative of lifespan in all environments
  • Inrush/holding and loss: Power consumption figures specify typical values during operation but do not guarantee performance or safety margins
  • Frequency: 50/60 Hz; Standards: CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
  • Physical size and weight: Width 1.77 in; Depth 3.62 in; Height 3.35 in; Net Weight 0.433 kg (dimensions approximate)
  • Other specs: Impedance 2 mΩ; Signalling Circuit: 25 to 400 Hz; Insulation: Rated Insulation Volts 690 V; Reversing: No; Fire Rating: UL 94 V1; Shock/Vibration: 8 G (Open), 15 G (Closed); Operating Times: 45–55 ms (Closing), 20–90 ms (Opening); Protective Cover: Yes
  • Certifications and compliance: The listed ratings do not imply certification or compliance beyond stated standards
  • Technical Specifications

    Country of Origin Korea, Republic of
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 24-60V AC/DC
    Number of Poles 3
    Full Load Amps-Inductive 25 A
    Full Load Amps-Resistive 40 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
    Reversing No
    Frame / Series / Class / Code TeSys
    HP @ 3 Phase - 575V 20 hp
    Enclosure NEMA Rating No Enclosure
    Series TeSys Deca
    Net Weight 0.433 kg
    Operating Time 45 to 55 ms (Closing), 20 to 90 ms (Opening)
    Max. Operating Watts 5.5 kW (at 220 to 230V AC 50 Hz AC-3), 11 kW (at 380 to 400V AC 50 Hz AC-3), 11 kW (at 415V AC 50 Hz AC-3), 11 kW (at 440V AC 50 Hz AC-3), 15 kW (at 500V AC 50 Hz AC-3), 15 kW (at 660 to 690V AC 50 Hz AC-3), 5.5 kW (at 220 to 230V AC 50 Hz AC-3e), 11 kW (at 380 to 400V AC 50 Hz AC-3e), 11 kW (at 415V AC 50 Hz AC-3e), 11 kW (at 440V AC 50 Hz AC-3e), 15 kW (at 500V AC 50 Hz AC-3e), 15 kW (at 660 to 690V AC 50 Hz AC-3e)
    Mechanical Durability 15 Mcycles
    Non-Overlap Time 1.5 ms
    Hold VA 0.9 VA
    Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
    Application Motor Control, Resistive Load
    Signalling Circuit Frequency 25 to 400 Hz
    Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
    Electrical Durability 2 Mcycles (21 A, AC-3, Less than 440 V); 0.9 Mcycles (40 A, AC-1, Less than 440 V); 2 Mcycles (21 A, AC-3e, Less than 440 V)
    Fire Rating UL 94 V1
    Rated Insulation Volts 690V
    Rated Breaking Capacity 450 A @ 440V