Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V-60V AC/DC, 3 P, Non-Reversing, Screw Clamp LC1D09BNE
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V-60V AC/DC, 3 P, Non-Reversing, Screw Clamp LC1D09BNE
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LC1D09BNE

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 24V-60V AC/DC, 3 P, Non-Reversing, Screw Clamp LC1D09BNE

Country of Origin Korea, Republic of
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 24-60V AC/DC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The IEC Magnetic Contactor is a 3-pole, non-reversing switching device rated for use in motor control and resistive-load applications within specified parameters. It is rated for coil voltages of 24 to 60 V AC/DC within specified ranges and includes one normally open and one normally closed auxiliary contact (2 total). The unit uses screw clamp terminals, is part of the TeSys Deca series, and includes protective cover; compatible with enclosure options as per installation requirements; protective cover included but does not guarantee environmental protection in all conditions. It is rated for up to 690 V and rated for operation at frequencies of 50/60 Hz within specified limits.

Key features

  • Poles/main contacts: 3 poles; 3 normally open main contacts
  • Auxiliary contacts: 2 total (1NO/1NC)
  • Coil voltage: 24–60 V AC/DC
  • Electrical ratings: based on standardized testing; actual performance may vary depending on conditions
  • Connection and enclosure: Screw Clamp terminals; compatible with enclosure options as per installation requirements; protective cover included but does not guarantee environmental protection in all conditions
  • Mechanical/electrical durability: durability ratings based on testing standards; actual lifespan depends on operating environment and usage patterns
  • Environmental/standards: IP20; impulse withstand: tested for impulse withstand up to specified voltage under controlled conditions; standards: conforms to applicable standards as listed; Reversing: Non-Reversing
  • Series/size: TeSys Deca; Frame/Code: TeSys
  • Mounting/installation: DIN Rail, Plate; Mounts On Plate, Rail
  • Physical dimensions: Width 1.77 in; Depth 3.38 in; Height 3.03 in (Overall Depth 3.39 in)
  • Operating parameters: Frequency 50/60 Hz; Max voltage rating 690 V; Signalling voltage 17 V (Signalling); Signalling current 5 mA
  • Weight: 0.368 kg
  • Other: Inrush VA 15 VA; Hold VA 0.9 VA; Impedance 2.5 mΩ; Impulse withstand: tested for impulse withstand up to specified voltage under controlled conditions; does not imply immunity from damage outside these parameters; Fire rating UL 94 V1; Reversing: No; Series: TeSys Deca
  • Technical Specifications

    Country of Origin Korea, Republic of
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 24-60V AC/DC
    Number of Poles 3
    Full Load Amps-Inductive 9 A
    Full Load Amps-Resistive 20 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
    Frame / Series / Class / Code TeSys
    Reversing No
    HP @ 3 Phase - 575V 7 1/2 hp
    Enclosure NEMA Rating No Enclosure
    Series TeSys Deca
    Operating Time 45 to 55 ms (Closing), 20 to 90 ms (Opening)
    Fire Rating UL 94 V1
    Includes Protective Cover Yes
    Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
    Mechanical Durability 15 Mcycles
    Overvoltage Category CAT III
    Electrical Durability 2.4 Mcycles (8 A, AC-3, Less than 440 V); 0.6 Mcycles (25 A, AC-1, Less than 440 V); 2.4 Mcycles (8 A, AC-3e, Less than 440 V)
    Application Motor Control, Resistive Load
    Watts Loss 0.6W
    Rated Short-Time Withstand Current 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit)
    Operating Speed 3600 cycles per hr
    Rated Insulation Volts 690V
    Switching Voltage 17 V (Signalling Circuit)
    IP Rating IP20
    Can't find it?
    We source what you need.
    Bookmarks
    Recently Viewed
    Compare