Home
→
Departments
→
Electrical Items
→
Industrial Electrical Controls & Automation
→
Electrical Controls
→
Electrical Contactors & Contacts
→
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 200V AC, 3 P, Non-Reversing, Screw Clamp LC1D65AL7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand
Schneider Electric
MFR#
LC1D65AL7
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 200V AC, 3 P, Non-Reversing, Screw Clamp LC1D65AL7
Country of Origin
Indonesia
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
200V AC
Search Similar Products
Uncheck any specs you want to ignore
Description
IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 200V AC, Number of Poles 3, Full Load Current - Inductive 65 A, Full Load Current - Resistive 80 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC
Technical Specifications
Country of Origin
Indonesia
Item
IEC Magnetic Contactor
Auxiliary Contact Form
1NC/1NO
Coil Voltage
200V AC
Number of Poles
3
Full Load Amps-Inductive
65 A
Full Load Amps-Resistive
80 A
Reversing Capability
Non-Reversing
Terminal Connection Type
Screw Clamp
Number of Auxillary Contacts
2
Standards
CCC, CSA, CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, UL Listed
HP @ 1 Phase - 230V
10
HP @ 3 Phase - 575V
50 hp
Enclosure NEMA Rating
No Enclosure
Reversing
No
Series
TeSys Deca
Includes
Everlink Power Connections
Rated Short-Time Withstand Current
520 A (at 40°C for 10 s Power Circuit), 900 A (at 40°C for 1 s Power Circuit), 110 A (at 40°C for 10 min Power Circuit), 260 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Electrical Durability
1.4 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (65 A, AC-3, Less than 440 V); 1.45 Mcycles (65 A, AC-3e, Less than 440 V)
Mechanical Durability
6 Mcycles
Switching Current
5 mA (Signalling Circuit)
Impedance
1.5 mOhm
Fuse Amps
10 A (Signalling Circuit), 125 A (Type 1 Power Circuit), 125 A (Type 2 Power Circuit)
Includes Protective Cover
Yes
Shock Resistance
10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed)
Inrush VA
140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C)
Control Circuit Voltage Limits
Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Signalling Circuit Frequency
25 to 400 Hz
Features
Without Built-In Suppressor Module
Operating Speed
3600 cycles per hr
Similar Products
Square D
SQUARE D Auxiliary Contact, 1NO/1NC, 5 A 9999D11
9999D11
Square D
SQUARE D Auxiliary Contact, 1NO/0NC, 10 A 9999SX6
9999SX6
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/2NC, 10 A LADN22
LADN22
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 1NO/1NC, 10 A LADN11
LADN11
Eaton
EATON Cutler-Hammer Auxiliary Contacts, 1NO-1NC, Size00-2 C320KGS3
C320KGS3
Schneider Electric
SCHNEIDER ELECTRIC Auxiliary Contact Block, 2NO/0NC, 10 A LADN20
LADN20
Square D
SQUARE D External Reset Mechanism Kit, PushButton 9066RA1
9066RA1
Square D
SQUARE D Control Kit, NEMA, Black Selector Switch 9999SC2
9999SC2
Can't find it?
We source what you need.