SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 200V AC, 3 P, Non-Reversing, Screw Clamp LC1D50AL7

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 200V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Schneider Electric IEC Magnetic Contactor, 3-pole, non-reversing, with a 200 V AC coil and 1 normally open/1 normally closed auxiliary contacts (2 auxiliary contacts total). It is an IEC-style magnetic contactor rated for switching power circuits for motor control and resistive loads, suitable for installation in control panels with standardized sizing.

Action: Non-Reversing

  • Poles: 3; Phase: Three
  • Coil Voltage: 200 V AC
  • Auxiliary Contacts: 2 total (1NO/1NC)
  • Main Contacts: 3 NO
  • Contactor Style: IEC
  • Application: Suitable for motor control and resistive load applications (see specifications).
  • Electrical Connection: Control Circuit: Screw Clamp Terminals; Power Circuit: EverLink BTR Screw Connectors
  • Includes: Power connections and protective cover as specified.
  • IP Rating / Enclosure: Rated at IP20; enclosure not included.
  • Mounting Style / Mounts On: Compatible with DIN rail or mounting plates as specified.
  • Dimensions: Dimensions are provided as approximate measurements based on product specifications.
  • Net Weight: Net weight is approximately 0.855 kg based on manufacturing data.
  • Rated Voltage: Rated voltage ranges are specified within the product's operational ratings (see specifications).
  • Series: Series designation only; does not imply performance guarantees beyond listed standards.
  • Reversing: Reversing function not included or supported by this model specification.
  • Overvoltage Category: Overvoltage category classification per standards but does not guarantee suitability under all conditions outside specified ratings.
  • Frequency: Frequency compatibility within standard operating ranges (see specifications).
  • Rated Making Capacity: Capacities are rated values based on testing conditions but do not imply continuous or guaranteed operation under all circumstances.
  • Rated Short-Time Withstand Current: 400 A (40°C, 10 s); 810 A (40°C, 1 s)
  • Mechanical Durability: 6 Mcycles
  • Electrical Durability: 1,100,000 to 1,450,000 cycles
  • Standards: EN 60947-4-1, EN 60947-5-1, UL 508, UL Listed, CSA, CSA C22.2 No 14
  • Fire Rating: UL 94 V1
  • Holding/Coil VA: 13 VA (60 Hz, 20°C); 15 VA (50 Hz, 20°C)
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 200V AC
    Number of Poles 3
    Full Load Amps-Inductive 50 A
    Full Load Amps-Resistive 80 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UL 508, UL Listed
    HP @ 1 Phase - 230V 7-1/2
    Reversing No
    HP @ 3 Phase - 575V 40 hp
    Enclosure NEMA Rating No Enclosure
    Series TeSys Deca
    Includes Everlink Power Connections
    Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
    Rated Breaking Capacity 900 A @ 440V
    Overvoltage Category CAT III
    Electrical Durability 1.45 Mcycles (50 A, AC-3, Less than 440 V); 1.1 Mcycles (80 A, AC-1, Less than 440 V); 1.45 Mcycles (50 A, AC-3e, Less than 440 V)
    Net Weight 0.855 kg
    Features Without Built-In Suppressor Module
    Rated Short-Time Withstand Current 400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
    Max. Operating Watts 15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e)
    Switching Voltage 17 V (Signalling Circuit)
    Application Motor Control, Resistive Load
    Includes Protective Cover Yes
    Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
    Rated Making Capacity 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit)