Brand Schneider Electric
MFR# LC1D32G7

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 120V AC, 3 P, Non-Reversing, Screw Clamp LC1D32G7

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 120V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The IEC Magnetic Contactor is a 3-pole, rated for switching power circuits within specified load parameters in IEC-based control systems. It uses a 120 V AC coil and screw clamp terminals, with auxiliary contacts configured as 1NO/1NC (2 total). Suitable for DIN rail or plate mounting; shipped without an enclosure (IP20). It belongs to the TeSys Deca series and includes a protective cover (not intended as safety certification).

Key features

  • Coil voltage: 120 V AC
  • Poles/phase: 3 poles; Three-phase
  • Auxiliary contacts: 2 total (1NO/1NC)
  • Main contacts: 3 normally open
  • Reversing: Rated for non-reversing operation within specified functions
  • Electrical connection: Screw Clamp Terminals
  • Mounting: DIN Rail, Plate
  • Enclosure/IP: No Enclosure; IP20
  • Frame/Series: TeSys Deca
  • Rated voltage / insulation: 690 V AC; Insulation 600/690 V
  • Full load currents: 32 A (Inductive); 50 A (Resistive) | rated for full load currents up to 32 A inductive / 50 A resistive under specified conditions
  • Maximum making capacity: 550 A @ 440 V (Power Circuit); 140 A (AC Signalling); 250 A (DC Signalling) | rated maximum making capacity of up to 550 A at 440 V in power circuit applications; capacities may vary based on actual operating conditions
  • Frequency: 50/60 Hz
  • Dimensions: Depth 3.62 in; Height 3.35 in; Width 1.77 in
  • Net weight: 0.375 kg
  • Operating times: Closing 12–22 ms; Opening 4–19 ms | typical operating times observed under test conditions, not guaranteed during all use cases
  • Coil hold VA: 7.5 VA @ 60 Hz; 7 VA @ 50 Hz | coil consumption ratings at specified frequencies, subject to actual application conditions
  • Impulse withstand voltage: 6 kV | tested impulse withstand voltage of up to approximately 6 kV, but performance may vary with application specifics
  • Shock resistance: 8 G (Open); 15 G (Closed) | shock resistance levels measured under specific test standards; actual resilience depends on installation and environment
  • Operating temperature: Maximum operating temperature 140°F | rated for operation within the specified temperature range, actual performance may vary based on environmental factors
  • Environmental attributes: Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
  • Includes protective cover: Yes -> Includes a protective cover (not intended as safety certification): Yes
  • Embedded surge suppressor: No
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 120V AC
    Number of Poles 3
    Full Load Amps-Inductive 32 A
    Full Load Amps-Resistive 50 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
    Reversing No
    Enclosure NEMA Rating No Enclosure
    Frame / Series / Class / Code TeSys
    HP @ 3 Phase - 575V 30 hp
    Series TeSys Deca
    Operating Speed 3600 cycles per hr
    Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)
    IP Rating IP20
    Inrush VA 70 VA
    Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
    Max. Operating Watts 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3), 15 kW (at 380 to 400V AC 50/60 Hz AC-3), 15 kW (at 415 to 440V AC 50/60 Hz AC-3), 18.5 kW (at 500V AC 50/60 Hz AC-3), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 7.5 kW (at 400V AC 50/60 Hz AC-4), 7.5 kW (at 220 to 230V AC 50/60 Hz AC-3e), 15 kW (at 380 to 400V AC 50/60 Hz AC-3e), 15 kW (at 415 to 440V AC 50/60 Hz AC-3e), 18.5 kW (at 500V AC 50/60 Hz AC-3e), 18.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
    Rated Breaking Capacity 550 A @ 440V
    Switching Current 5 mA (Signalling Circuit)
    Non-Overlap Time 1.5 ms
    Includes Protective Cover Yes
    Fire Rating UL 94 V1
    Fuse Amps 10 A (Signalling Circuit), 63 A (Type 1 Power Circuit), 63 A (Type 2 Power Circuit)
    Electrical Durability 1.65 Mcycles (32 A, AC-3, Less than 440 V); 1.4 Mcycles (50 A, AC-1, Less than 440 V); 1.65 Mcycles (32 A, AC-3e, Less than 440 V)
    Environmental Attributes Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3