Part of the NOVA Platform ecosystem · Kampala, Uganda · sales@redgroundonline.com · WhatsApp +256 755 978 947
ℹ About ❓ How it Works ✉ Contact 🔑 Sign In
Submit RFQ Request →
Categories
Sub-Categories
Home → Departments → Electrical Items → Industrial Electrical Controls & Automation → Electrical Controls → Electrical Contactors & Contacts → SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 110V AC, 3 P, Non-Reversing, Screw Clamp LC1D12F7
SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 110V AC, 3 P, Non-Reversing, Screw Clamp LC1D12F7
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Schneider Electric
MFR# LC1D12F7

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 110V AC, 3 P, Non-Reversing, Screw Clamp LC1D12F7

Country of Origin Indonesia
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 110V AC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The item is an IEC Magnetic Contactor (TeSys Deca) with three poles and a 110 V AC coil. It is a non-reversing device with 1 normally open and 1 normally closed auxiliary contacts (2 total), and uses screw clamp terminals for wiring. Rated for switching power circuits within the specified IEC standards. It is suitable for use with motor control and resistive loads when used according to manufacturer instructions, and is provided without an enclosure; rated IP20 for indoor use only.

Key features

  • Coil voltage: 110 V AC
  • Poles/Main contacts: 3 main normally open contacts
  • Auxiliary contacts: 2 total (1NO/1NC)
  • Reversing: Non-Reversing
  • Electrical connection: Screw Clamp Terminals
  • Series/Frame: TeSys Deca (IEC)
  • Frequency: 50/60 Hz
  • Maximum voltage rating: 690 V AC
  • Full Load Amps: 25 A (resistive); 12 A (inductive)
  • Enclosure: No Enclosure; IP20 (indoor use only)
  • Weight: 0.325 kg
  • Dimensions: Depth 3.39 in; Height 3.03 in; Width 1.77 in
  • Mounting: DIN Rail, Plate; Mounts On: Plate, Rail
  • Protective cover: Includes protective cover
  • Standards: EN 60947-4-1, EN 60947-5-1, UL 508, UL Listed, CSA, CSA C22.2 No 14, and others
  • Technical Specifications

    Country of Origin Indonesia
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 110V AC
    Number of Poles 3
    Full Load Amps-Inductive 12 A
    Full Load Amps-Resistive 25 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards BV, CCC, CSA, CSA C22.2 No 14, DNV, EN 60947-4-1, EN 60947-5-1, GL, GOST, IEC 60335-1, IEC 60947-4-1, IEC 60947-5-1, LROS, RINA, UKCA, UL 508, UL Listed
    Frame / Series / Class / Code TeSys
    Series TeSys Deca
    Reversing No
    HP @ 3 Phase - 575V 10 hp
    Enclosure NEMA Rating No Enclosure
    Hold VA 7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
    Max. Operating Watts 3 kW (at 220 to 230V AC 50/60 Hz AC-3), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3), 7.5 kW (at 500V AC 50/60 Hz AC-3), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 3.7 kW (at 400V AC 50/60 Hz AC-4), 3 kW (at 220 to 230V AC 50/60 Hz AC-3e), 5.5 kW (at 380 to 400V AC 50/60 Hz AC-3e), 5.5 kW 415 to (at 440V AC 50/60 Hz AC-3e), 7.5 kW (at 500V AC 50/60 Hz AC-3e), 7.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
    Control Circuit Voltage Limits Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz); Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
    Switching Current 5 mA (Signalling Circuit)
    Operating Time 12 to 22 ms (Closing), 4 to 19 ms (Opening)
    Non-Overlap Time 1.5 ms
    Rated Making Capacity 250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
    Rated Insulation Volts 600V, 690V
    Rated Breaking Capacity 250 A @ 440V
    Tightening Torque 1.7 Nm
    Shock Resistance 15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
    Features Without Built-In Suppressor Module
    Rated Short-Time Withstand Current 105 A (at 40 Degrees C for 10 s Power Circuit), 210 A (at 40 Degrees C for 1 s Power Circuit), 30 A (at 40 Degrees C for 10 min Power Circuit), 61 A (at 40 Degrees C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
    Operating Speed 3600 cycles per hr
    Can't find it?
    We source what you need.
    Bookmarks
    Recently Viewed
    Compare