Brand Schneider Electric
MFR# LC1D09KUE

SCHNEIDER ELECTRIC IEC Magnetic Contactor, 1NC/1NO, 100V-250V AC/DC, 3 P, Non-Reversing, Screw Clamp LC1D09KUE

Country of Origin France
Item IEC Magnetic Contactor
Auxiliary Contact Form 1NC/1NO
Coil Voltage 100-250V AC/DC

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

The Schneider Electric IEC Magnetic Contactor is a 3-pole, non-reversing, electromagnetically operated switch rated for operation within specified motor control and resistive-load application parameters. It uses a coil voltage range of 100–250 V AC/DC and features two auxiliary contacts configured as 1NO/1NC. The device uses screw clamp terminals and is part of the TeSys Deca family, rated for operation up to 690 V AC within specified conditions, with a 50/60 Hz operating frequency.

Key features

  • Poles/contacts: 3 main poles; 3 normally open main contacts; 2 auxiliary contacts (1NO/1NC)
  • Coil voltage: 100–250 V AC/DC
  • Reversing: Non-Reversing
  • Electrical ratings: rated for operation up to 690 V AC within specified conditions; 50/60 Hz; Rated making capacity up to 250 A at 440 V under standard test conditions; Full load currents of up to 20 A resistive and 9 A inductive loads within specified ratings
  • Mechanical/thermal: Mechanical durability 15 Mcycles; Electrical operating durability 2,400,000 cycles
  • Physical/dimensions: Width 1.77 in; Height 3.03 in; Depth 3.39 in; Net weight 0.368 kg; IP20; No enclosure
  • Mounting/installation: Mounting style DIN Rail, Plate; Mounts on Plate, Rail; Screw Clamp terminals
  • Series/standards: TeSys Deca; Standards include UL Listed and EN/IEC 60947-4-1, EN/IEC 60947-5-1
  • Other features: Includes protective cover; Does not include an integrated surge suppression device; Fire rating: UL 94 V1
  • Phase/frequency: Three-phase; 50/60 Hz
  • Temperature ratings: Rated for operation within the specified temperature ranges
  • Technical Specifications

    Country of Origin France
    Item IEC Magnetic Contactor
    Auxiliary Contact Form 1NC/1NO
    Coil Voltage 100-250V AC/DC
    Number of Poles 3
    Full Load Amps-Inductive 9 A
    Full Load Amps-Resistive 20 A
    Reversing Capability Non-Reversing
    Terminal Connection Type Screw Clamp
    Number of Auxillary Contacts 2
    Standards CCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
    Frame / Series / Class / Code TeSys
    HP @ 3 Phase - 575V 7 1/2 hp
    Reversing No
    Enclosure NEMA Rating No Enclosure
    Series TeSys Deca
    Impulse Withstand Voltage 6 kV
    Hold VA 1.6 VA
    Non-Overlap Time 1.5 ms
    Includes Protective Cover Yes
    Application Motor Control, Resistive Load
    Tightening Torque 1.7 Nm
    Rated Breaking Capacity 250 A @ 440V
    Rated Insulation Volts 690V
    Overvoltage Category CAT III
    Insulation Resistance Range Greater Than 10 MOhms (Signalling Circuit)
    Operating Speed 3600 cycles per hr
    Max. Operating Watts 2.2 kW (at 220 to 230V AC 50 Hz AC-3), 4 kW (at 380 to 400V AC 50 Hz AC-3), 4 kW (at 415V AC 50 Hz AC-3), 4 kW (at 440V AC 50 Hz AC-3), 5.5 kW (at 500V AC 50 Hz AC-3), 5.5 kW (at 660 to 690V AC 50 Hz AC-3), 2.2 kW (at 220 to 230V AC 50 Hz AC-3e), 4 kW (at 380 to 400V AC 50 Hz AC-3e), 4 kW (at 415V AC 50 Hz AC-3e), 4 kW (at 440V AC 50 Hz AC-3e), 5.5 kW (at 500V AC 50 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50 Hz AC-3e)
    Fuse Amps 10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
    Vibration Resistance 4 G (Contactor Closed), 2 G (Contactor Open)