Home → Departments → Electrical Items → Cables & Wires → Electrical Power & Industrial Cables → Building Wire & Cable → SOUTHWIRE Metal Clad Building Cable, MC; FPLP, 14 AWG, 2C with Ground C, Red, Aluminum, Solid, 600V AC 55469002
SOUTHWIRE Metal Clad Building Cable, MC; FPLP, 14 AWG, 2C with Ground C, Red, Aluminum, Solid, 600V AC 55469002
Verified Sourcing
Import & Local Stock
Flexible Payment
Brand Southwire
MFR# 55469002

SOUTHWIRE Metal Clad Building Cable, MC; FPLP, 14 AWG, 2C with Ground C, Red, Aluminum, Solid, 600V AC 55469002

Country of Origin United States
Item Metal Clad Building Cable
Trade Designation MC; FPLP
Conductor Material Copper

Specify quantity and delivery requirements when submitting your RFQ

WhatsApp Email

Description

Metal Clad Armored Cable, Trade Designation MC-FPLP, Wire Size 14 AWG, Number of Conductors 2, Wire Color Black/Green/White, Jacket Color Red, Length 250 ft, Conductor Design Solid, Jacket Material Aluminum, Insulation Material PVC, Nominal Outside Dia. 0.44 in, Packaging Coil, Voltage 600 V, Temp. Rating -6.8 Degrees to 194 Degrees F Dry

Technical Specifications

Country of Origin United States
Item Metal Clad Building Cable
Trade Designation MC; FPLP
Conductor Material Copper
Number of Conductors 2C with Ground
Wire Color Black/Green/White
Jacket Color Red
Jacket Material Aluminum
Conductor Design Solid
Insulation Material PVC
Voltage 600 V
Temp. Rating -6.8 Degrees to 194 Degrees F Dry
Standards NEC 2011, Approved for The State of Rhode Island Fire Systems, A-A-59544, IEEE 1202, Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems, NFPA 262-2002, NFPA 70, UL 1063, UL 1424, UL 1569, UL 83, Vertical Cable Tray Flame Test
Application Indoor
Max. Amps 15 A
Stranding 1
Packaging Coil
Shielding Shielded
Shielding Material Aluminum
Applications ApplicationRed Alert® Type MC-FPLP Cable is suitable for use as follows:Wiring in Plenums, Ducts or Other Spaces Used for Environmental Air-Handling Purposes per NEC 300.22(C) & 760.135(C).Power-Limited and Non-Power Limited fire alarm circuits, including smoke detectors, bells, horns, fire alarm control panel equipment, and initiation and signaling devicesClass 1, Class 2, and Class 3 remote control, signaling, and power-limited circuits.Power, lighting, control, and signal circuits.Fished or embedded in plasterConcealed or exposed installations.Places of Assembly per NEC 518.4 and Theaters per NEC 520.5.Installation in cable tray and approved raceways.Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
Construction ConstructionType TFN conductors are provided for sizes 18 AWG and 16 AWG cables. The cable is dual rated as 90°C dry, 600 Volt Type MC and 105°C dry, 300 Volt Type FPLP cable.
Number of Ground Conductors 1
Operating Temperature - Minimum -6.8 Degrees F
Trade Designation - Conductors THHN
Series Red Alert(R) Type MC-FPLP
Number of Strands 1
Includes Bonding Wire No Bonding Wire
Grounding Conductor Insulation Color Green
Number of Neutrals 0
Grounding Conductor Material Copper